Cut Sheet

V1-T5-82 Volume 1—Residential and Light Commercial CA08100002E—March 2015 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.5
Power Pedestals
Marina Power and Lighting Equipment
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-54
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-58
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-65
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-69
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-73
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-79
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-80
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-81
Distribution Equipment—Ground Fault Monitor
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-83
Distribution Equipment—Substations . . . . . . . . . . V1-T5-86
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-89
Distribution Equipment—Transformers . . . . . . . . . V1-T5-90
Distribution Equipment—Ground Fault Monitor
Product Description
Our ground fault monitoring
systems are designed to
detect fault currents in the
AC shore power system that
are too low to trip a circuit
breaker. The ground fault
monitor helps reduce the risk
of injury or property damage
that may result from stray
fault currents. Our ground
fault monitoring system
provides information to the
maintenance staff on the
overall condition of the AC
electrical system. The ground
fault monitoring system
operates 24 hours a day and
can be monitored by non-
technical personnel.
Features
Adjustable trip level 10 mA
to 10 A
Current transformers up to
8 1/4-inch diameter
Visual and/or audible alarm
Housing of fiberglass or
powder-coated stainless
steel available
Power Guard
The ground fault monitor
detects ground fault currents
by means of current
transformers (CT), which are
placed around main or branch
circuits. If a ground fault
occurs, the CT will detect the
amount of fault current and
send a signal to the ground
fault monitoring device where
the amount of fault current is
displayed with the faulty
circuit identified. The
detected fault can either
activate an indicator alarm or
disconnect the faulted circuit.
Standards and Certifications
UL listed current
transformers