Power Pedestals
Marina Power and Lighting Equipment
Three-Phase Transformer
Contents
Description Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-51
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-54
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-58
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-62
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . V1-T5-65
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-69
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-73
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-79
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-80
Digital Electronic Kilowatthour Meters. . . . . . . . . . V1-T5-81
Distribution Equipment—Ground Fault Monitor. . . V1-T5-82
Distribution Equipment—Mega Yacht Powerpoint . V1-T5-83
Distribution Equipment—Substations . . . . . . . . . . V1-T5-86
Distribution Equipment—Panels . . . . . . . . . . . . . . V1-T5-89
Distribution Equipment—Transformers
Distribution Equipment—Transformers
Product Description
Because of the high humidity
and corrosive conditions of
coastal environments, our
transformers are wound with
Class H heavily insulated
copper bar and are double
dipped in tough insulating
varnish that protects the
copper, as well as reduces
the hum that is typical in
a transformer that is not
double dipped. We provide
a second overcoat of high
temperature epoxy to protect
against the severe saltwater
environment. We can provide
this transformer in single-
phase, from 50 to 500 kVA,
and three-phase, from
45 to 300 kVA.
Features
Copper wound transformer
coils double dipped in high
temperature baking varnish
All internal wiring is
fine stranded 2000 V
insulated copper
Copper busbars
Marine transformers
with epoxy overcoat
All copper-to-copper
connections
Available Options
Single-phase: 50–500 kVA
Three-phase: 45–300 kVA
Epoxy overcoat for non-
marine applications
Primary Voltages
480 wye three-phase
480 V three-phase delta
three-wire + ground
480 V single-phase
two-wire + ground
Secondary Voltages
127/220 V three-phase
wye four-wire
120/208 V three-phase
wye four-wire
120/240 V single-phase
three-wire
Marina Power Distribution
Transformer kVA Availabilities
Single-phase: 50, 75, 100,
150, 167.5, 200, 250, 330,
500 kVA
Three-phase: 45, 75, 112.5,
150, 225, 300 kVA
Standards and Certifications