1.2
Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Contents
Description Page
Overview
Product Description . . . . . . . . . . . . . . . . . . . . . V1-T1-43
Features, Benefits and Functions . . . . . . . . . . V1-T1-43
Standards and Certifications . . . . . . . . . . . . . . V1-T1-45
Catalog Number Selection. . . . . . . . . . . . . . . . V1-T1-45
Product Selection. . . . . . . . . . . . . . . . . . . . . . . V1-T1-46
BR Specialty Products
BR Quick Connect Neutral Loadcenters . . . . . V1-T1-57
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-58
Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-59
Type BR Renovation Loadcenter . . . . . . . . . . . V1-T1-60
Type BR Mechanical Interlock Kits . . . . . . . . . . V1-T1-62
Type BR Retrofit Interior Kits . . . . . . . . . . . . . . V1-T1-73
BR Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-76
Overview
Product Selection Guide
BR Loadcenters
Description
Service
Single-phase, three-wire, 120/240 Vac Three-phase, four-wire, 208Y/120 Vac
Three-phase, three-wire, 240 Vac delta
Short-Circuit Current Rating
10 kAIC: All single- and three-phase loadcenters 70–225 A, 8 to 42 circuits
22 kAIC: All convertible loadcenters using 125 A rated Type BRH main breakers or
selected factory installed 125 A rated Type BRH main breaker
25 kAIC: All convertible and factory-installed single-phase loadcenters rated
150 and 200 A using Type CSR main breakers
Main Breaker/Main Lug Loadcenters
Single-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600 A
Main lugs: 70, 125, 150, 200, 225, 400, 600 A
Three-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600 A
Main lugs: 100, 125, 150, 200, 225, 400, 600 A
Convertible Loadcenters
Main breaker: single-phase up to 200 A and three-phase up to 225 A Main lugs: single-phase up to 200 A and three-phase up to 150 A
Branch Breakers
Types BR, BRH and BRHH: 10–150 A. single-, two- and three-pole; selected amperage
available in switching duty, HACR, shunt trip and high magnetic setting
Type GFCB: 15–60 A
Types BJ and BJH: 125–225 A; two- and three-pole
Type BD Twin: 10–50 A; two of one-pole; take one 1-inch (25.4 mm) space
Type BQ and BQC Multibreaker: 15–30 A. Two of two-pole or one two-pole and
two one-pole; takes two 1-inch (25.4 mm) spaces
Type BRW: 15–30 A; two-pole water heater breakers
Type BRSN: 15–30 A; two-pole switching neutral breakers
Type BR 15–100 A; two-pole, 240 Vac delta breakers
BR-AFCI arc fault circuit interrupter
Enclosures
NEMA Type 1 indoor
NEMA Type 3R outdoor
NEMA 4X
Meets or exceeds UL requirements for indoor or outdoor applications
Loadcenter and Breaker Accessories
Branch circuit breaker:
Auxiliary components Hold-down kits Handle ties
Lockoffs Lockdogs
Complete line of ground bar kits 5, 10, 14 and 21 circuit, some with additional #2/0 lugs;
each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
Main and sub-feed lugs 125, 150, 225 A—two- and three-pole
Shunt trips
Surge protection:
Single-phase plug-on surge protector Single-phase bottle type surge protector
Three-phase bottle type surge protector Single-phase whole home surge protector
Universal rainproof conduit hubs
Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm)
Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)
Adapter plate
Bussing
Tin-plated aluminum as standard Limited copper bus panels available