Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers
Contents
Description Page
Overview
Product Description . . . . . . . . . . . . . . . . . . . . . V1-T1-3
Features, Benefits and Functions . . . . . . . . . . V1-T1-3
Standards and Certifications . . . . . . . . . . . . . . V1-T1-4
Catalog Number Selection. . . . . . . . . . . . . . . . V1-T1-6
Product Selection. . . . . . . . . . . . . . . . . . . . . . . V1-T1-7
Technical Data and Specifications . . . . . . . . . . V1-T1-29
CH Specialty Products . . . . . . . . . . . . . . . . . . . . . V1-T1-14
CH Loadcenter Options and Accessories . . . . . . . V1-T1-22
CH Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31
Overview
Product Selection Guide
CH Loadcenters
Description
Service
Single-phase, three-wire, 120/240 Vac
Three-phase, three-wire, 240 V corner grounded delta
Three-phase, four-wire, 208Y/120 Vac
Three-phase, three-wire, 240 Vac delta
Short-Circuit Current Rating
10 kAIC: All single- and three-phase loadcenters 40–400 A, 2–42 circuits except when
series ratings are applied
25 kAIC: All factory-installed main breakers single-phase loadcenters rated 150–225 A
using Type CSR main breakers
35 kAIC available on convertible units using CSH main breaker
42 and 100 kAIC are available on some styles: single-phase and three-phase
Main Breaker/Main Lug Loadcenters
Single-phase
Main breaker: 100, 125, 150, 200, 225, 400 A
Main lugs: 40, 70, 125, 150, 200, 225, 400 A
Three-phase
Main breaker: 150, 200, 225, 300, 400 A
Main lugs: 125, 150, 200, 225, 400 A
Convertible Loadcenters
Main breaker or main lugs: single-phase up to 225 A
Branch Breakers
Type CH: 10–150 A. Single-, two- and three-pole. Selected amperages available in shunt
trip, HACR and switching duty
Ground fault circuit interruptors: 15–60 A
Type CH-HID: 15–30 A. Single-, two- and three-pole
CH-HM high magnetic
CH-M50 high ambient
Type CH-AFCI arc fault circuit interrupter
Type CHP: 10–125 A. Single-, two- and three-pole. three-position commercial trip
Selected amperages available in HACR switching duty
Type CHP-HID: 15–30 A. Single-, two- and three-pole
Type CHP-GFCI: 15–30 A. Single-pole ground fault breakers
Enclosures
NEMA
®
Type 1 indoor NEMA Type 3R outdoor
Loadcenter and Breaker Accessories
Branch circuit breaker:
Auxiliary components
Hold-down kits
Handle ties
Lockoffs
Lockdogs
Complete line of ground bar kits 5, 10, 14 and 21 circuits, some with additional #2/0 lugs
Each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
Sub-feed lugs 125, 150 A—two- and three-pole
Shunt trips
Universal rainproof conduit hubs Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm)
Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)
Adapter plate
Bussing
Silver flash plated copper bus is a standard feature