1.2
Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
BR Specialty Product Selection
To select the retrofit kit:
1. From the existing box
size determine which
retrofit groups are
suitable (may be more
than one).
2. Use type of interior,
number of phases, and
type of main to find the
selection chart.
3. Select part number from
chart (if main breaker,
replace XXX with specific
amp rating).
4. Note that the overlap
of the existing wall is
the retro cover size
minus the existing
box size. If specific
measurements are
needed, communicate
that you need a custom
trim size.
5. Contact the Lincoln Flex
Center at 800-330-6479
for pricing, lead-times,
and order entry
instructions.
How to Order:
1. Measure the existing
panel enclosure to
determine appropriate
kits for your project.
2. Match the existing
dimensions with the
table below to obtain the
correct catalog number.
3. Order your retrofit kit
from a local Eaton
authorized distributor.
Need assistance or can’t find
retrofit to fit existing
enclosure?
Call Eaton’s Residential Flex
Center at 1-800-330-6479
or email for all your retrofit
needs. Go to
www.eaton.com/eccn to
locate an Eaton Certified
Contractor.
Retrofit Interior Kit Specifications
Five recommended groups: existing box height determines retro group size. Approximate Dimensions in Inches (mm).
Notes
1
Catalog numbers shown with "_" at the end need one of the following suffixes to denote depth:
J = 3.75–4.25
K = 4.25–5.00
L = 5.00–6.00
Example: RTBR12L125J would signify an interior set with a depth range of 3.75 to 4.25 inches.
2
****Denotes characters in the catalog number that relate to overall cover size.
Example: CRTBR12ML2620 would signify a cover 26.00 inches H x 20.00 inches W.
3
Amperes for MB panels is maximum; catalog number will reflect actual amperage of breaker included.
For UL applications, maximum cover sizes may apply.
Existing Enclosure Parameters—Inches (mm)
Catalog
Number
1
Cover
2
Minimum
Depth
Maximum
Depth
Minimum
Width
Minimum
Height Phase Main Bus Amperes
3
Spaces /
Circuits
UL 67
Listed
BR Retrofit Interiors and Covers
RTBR8L100P CRTBR8ML**** 3.13 (79.5) 3.63 (92.2) 10.50 (266.7) 13.00 (330.2) Single MLO BR 100 16 Yes
RUBR8L100_ CRUBR8ML**** 3.75 (95.3) 6.00 (152.4) 10.50 (266.7) 13.00 (330.2) Single MLO BR 100 16 Yes
RTBR12L100P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 10.50 (266.7) 14.50 (368.3) Single MLO BR 100 24 Yes
RTBR10B100P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 10.50 (266.7) 14.50 (368.3) Single MLO BR 100 20 Yes
RUBR12L100_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 10.50 (266.7) 14.50 (368.3) Single MLO BR 100 24 Yes
RUBR10B100_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 10.50 (266.7) 14.50 (368.3) Single MB BR 100 20 Yes
RTBR12L125P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 11.00 (279.4) 17.00 (431.8) Single MLO BR 125 24 Yes
RTBR10B125P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 11.00 (279.4) 17.00 (431.8) Single MB BR 125 20 Yes
RUBR12L125_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 11.00 (279.4) 17.00 (431.8) Single MLO BR 125 24 Yes
RUBR10B125_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 11.00 (279.4) 17.00 (431.8) Single MB BR 125 20 Yes
RABR20B125_ CRABR20ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 21.00 (533.4) Single MCB BR 125 24 No
RABR20L125_ CRABR20ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 21.00 (533.4) Single MLO BR 125 24 No
RBBR20B200_ CRBBR20BW**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 29.00 (736.6) Single MLO BR 200 40 No
RCBR40L200_ CRCBR40ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 34.00 (863.6) Single MLO BR 200 40 No
RDBR40B200_ CRDBR40BW**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 37.00 (939.8) Single MLO BR 200 40 No