Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Plug-On Circuit Breakers, Types BJ and BJH—10/22 kAIC, 120/240 Vac and 240 Vac
For Use in Single-Phase and Three-Phase Loadcenters—150 Amperes and Above
Types BJ and BJH Breakers, 1-Inch (25.4 mm) per Pole, 120/240 or 240 Vac, 10, 22 kAIC
Plug-On Special Application Circuit Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 Vac
Special Application Circuit Breakers, 1-Inch (25.4 mm) per Pole
Notes
1
Breaker uses two 1-inch (25.4 mm) pole spaces on left side and two 1-inch (25.4 mm) pole spaces on right side of loadcenter.
2
Breaker uses three 1-inch (25.4 mm) pole spaces on left side and three 1-inch (25.4 mm) pole spaces on right side of loadcenter.
If BJ or BJH breakers are used as a main or a back feed device, a hold-down kit is required. See Page V1-T1-85
.
Ampere
Rating
Wire Size Range
Cu/Al 60 °C or 75 °C
Two-Pole 120/240 Vac
Common Trip Requires Four
1-Inch (25.4 mm) Spaces
1
10 per Shelf Carton
Three-Pole 240 Vac
Common Trip Requires Six
1-Inch (25.4 mm) Spaces
2
5 per Shelf Carton
10 kAIC 22 kAIC 10 kAIC 22 kAIC
Catalog Number Catalog Number Catalog Number Catalog Number
125 BJ2125 BJH2125 #2–300 kcmil BJ3125 BJH3125
150 BJ2150 BJH2150 #2–300 kcmil BJ3150 BJH3150
175 BJ2175 BJH2175 #2–300 kcmil BJ3175 BJH3175
200 BJ2200 BJH2200 #2–300 kcmil BJ3200 BJH3200
225 BJ2225 BJH2225 #2–300 kcmil BJ3225 BJH3225
Water Heater Breakers Switching Neutral Breakers
Wire
Size
Range
Cu/Al
60 °C or
75 °C
240 V Breakers Non-Automatic Molded Case Switches
Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
Two-Pole 120 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
Two-Pole 240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
Two-Pole 240 Vac
Requires Two
1-Inch (25.4 mm) Spaces
With Isolated Line Terminals
for Separately Metered
Water Heaters
With Switching Neutral Pole
for Gasoline Pump Applications
Where Voltage to
Ground is 240 Vac
For Use as Disconnect Contains No
Magnetic or Thermal Trip Properties
5 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton
10 kAIC 10 kAIC 10 kAIC 5 kAIC
Ampere
Rating
Catalog
Number
Ampere
Rating
Catalog
Number
Ampere
Rating
Catalog
Number
Ampere
Rating
Catalog
Number
15 BRWH215 15 BRSN215 #14–4 10 BR210H
20 BRWH220 20 BRSN220 #14–4 15 BR215H
30 BRWH230 25 BRSN225 #14–4 20 BR220H
30 BRSN230 #14–4 25 BR225H
#
14–4 30 BR230H
#14–4 35 BR235H
#14–4 40 BR240H
#14–4 45 BR245H
#14–4 50 BR250H 50 BR250NA
#14–4 55 BR255H
#4–1/0 60 BR260H 60 BR260NA
#4–1/0 70 BR270H
#4–1/0 80 BR280H
#4–1/0 90 BR290H
#4–1/0 100 BR2100H 100 BR2100NA
Type BJ
BRWH215
Water Heater Breaker
BRSN220
Switching Neutral
Breaker
LINE
LOAD
OUT
IN
NEUTRAL