Here you can define a name for the different Safety Inputs. There is a max. of 10 Safety Inputs
available. It is also possible to define the texts of the status messages to be displayed.
Field 2:
Under ”Status Alarm“ you can define in which status the alarm should be triggered.
Field 3:
With ”Activate with delay“ you have the possibility to activate or deactivate the individual Safety
Inputs with a delay after the circuit has been armed. Also refer to Field 8.
Field 4:
Within the time period you preset here, the Room Manager expects to receive a status message
from the Safety Input. If the Room Manager does not receive a status message within that preset
time, the alarm will be triggered.
Field 5:
Under “Zone“ you can assign the Safety Inputs to the different safety zones (zone 1, zone 2,
zone1+2)
Field 6:
Here you can display the names of the RF sensors that have been assigned.
Field 7:
In addition to the 10 Safety Inputs you can also add 3 window contacts of the rooms to the Safety
Function and keep them under surveillance.
Field 8:
Here you can set the time period for the delay after activating the Safety Function, this means that
if the safety function is activated, all the inputs with a preset delay time will only be armed after the
preset delay time, whereas all the other inputs will be armed immediately after activation.
Also refer to chapter Room Manager with Safety Function - Overview
Room Manager with Safety Function - Smoke Detector:
This is what the configuration window for the smoke detector looks like: