Technical information

122 Eaton RF-System - Help
© 2013 Eaton Electrical Group
Set/interrogate marker by SMS If this option is activated also state of markers can be requested
and set by SMS-commands
Shading can be controlled by SMS If this option is activated also the state of shadings can be
controlled by SMS-commands
To be able to operate inputs and outputs by SMS-commands use the check boxes on the
output-/input-configuration page.
Mobile phone selection Manufacturer and type of the mobile phone can be selected here ,
ATTENTION: The file “handy.txt” must be located in the same directory of the MRF program to be
able to select anything here.
Syntax from User-SMS for questioning and controlling of objects:
Beginning of every SMS: ":<Password> "
afterwards: "<object name>"
following: for request "?"
for control "=<state>!"
There is the possibility to request or control more than one object with only 1 SMS.
Examples: ":1234 R1?" Requesting the state of Room 1
":1234 O2=0!" Switches output 2 to OFF
":1234 R1? O1=1! I?" Requests the state of Room 1 and every input
and switches output 1 to ON
If more than one objects is requested, every information is integrated in one answer SMS or it is
separated in more SMS if the length exceeds a maximum of 160 characters.
<Password>:
4-16 characters alpha numeric, can be set in the MRF configuration window or in the
Room-Manager, is immediately following the “:” and ends with the first blank space afterwards
<<Object name>:
The object name defines which object should be operated, you can use either the full name of the
object or a short form.