Technical information
124 Eaton RF-System - Help
© 2013 Eaton Electrical Group
Basic information for Room-Manager Bluetooth:
The primary function for the Room-Manager Bluetooth is:
-) External control (via SMS) of Room-Manager objects (Outputs, shading, operation mode,…)
-) Sending of state information-SMS if requested by user
-) Triggering defined actions on the Room-Manager if a call is received
-) Sending of alert-SMS if defined events will occur
-) Triggering a call from the Room-Manager to a defined phone number if a defined event will
occur
-) Display of up to 5 received Text-SMS (for information purpose)
By using the integrated Bluetooth-module the Room-Manager establishes a connection to a
Bluetooth-mobile phone in its immediate surrounding. Over that mobile phone the Room-Manager
then can communicate via GSM with other mobile phones (Sending/receiving SMS,
Execute/receive calls,…).
To establish a connection to a mobile phone you have to first select the manufacturer and phone
type in the MRF configuration window ‘Bluetooth/SMS’ and load the information to the
Room-Manager.
Because not every mobile phone is acting the same it is recommended to only use devices that
has been tested by Eaton.
The real connection to the mobile phone must be done by using the Room-Manager menu ‘
Bluetooth’ and the command ‘Search for devices’.
Also see:
Room-Manager with Bluetooth-Function – Common settings
Room-Manager with Bluetooth-Function - Calls
Room-Manager with Bluetooth-Function - Alerts
Room-Manager with Bluetooth-Function – Text template
Syntax for Request/Control by SMS
Software download over IrDA-interface
To update the software of your Room Manager do the following:
1. Scan the Room Manager that you want to update with the MRF software
2. Make sure that you have the IrDA-interface of you PC/laptop activated.
3. Activate the IrDA-interface of you Room Manager by „Miscellaneous -> For the
installer -> Software update“, you now have 2 minutes time to establish
connection between your PC and the Room Manager.
4. Establish intervisibility between the IrDA-interface of your PC and the Room
Manager now
5. Now use the start menu of your operating system to: „Start -> Configuration ->
System configuration -> Telephone and modem options -> Register:
Modems“. A „standard mode over IR-link should be displayed.
6. In the row „assigned to“ you can see which COM-interface number your Room