The following settings can be done:
-) automatic changing of the clocks from summer time to winter time and vice versa
-) the operator’s code and whether it should be requested every time
-) the time the display should stay active – in seconds
In addition, it also displays the hard and software version of the remote control.
Also refer to chapter General Information on the Remote Control with Display
Remote Control with Display - Software update:
In order to carry out a software update on your remote control, please proceed as follows:
1. Via RF, read in the remote control into which you want to load the new software,
2. Make sure your infrared interface at the PC/Laptop has been activated
3. Activate the infrared interface of the Remote Control via “General Information” ->
”Software update“, you have only 2 minutes time to set up a connection
4. Establish a line of sight between the infrared interface of your PC and the infrared
interface of the remote control (at the rear under the battery cover).
5. Under the Windows Start menu -> Settings -> System control -> Phone and
modem options -> Tab: Modems you will see the remote control displayed as
“Standard Modem over IR Link“.
6. Under “Assigned to“ you can see which COM interface has been assigned to the
remote control.
7. Right-click the remote control in MRF and select the item “Load new software”