The control of the operation mode is done by the Room-Manager (timer program or manual). It can
be defined if the actual temperature and set value preset is given b the Room-Manager or the
radiator.
In this mode window contacts must only be assigned to the room of the Room-Manager and not to
the heating actuator separately.
You can also set how the heating actuator will react after a power failure.
Backup mode As long as no new control commands or temperature commands are received by
its assigned devices all control commands will come from the connected radiator.
old value It does axaclty the same than before power failure until new commands and
temperature are received
BOS/COS Interface
The BOS/COS interface has the purpose to integrate occupancy sensors such as bed- or
chair-occupancy sensors in the Eaton RF System especially for the Elderly care function.
The device is mains supplied and contains of 2 RJ11 jacks to which the sensors can be