Technical information
156 Eaton RF-System - Help
© 2013 Eaton Electrical Group
Assigned device:
In the stand alone operation there is no assigned device. Furthermore
the function „send own temperature to intelligent device“ is not used.
Request/Regulation time:
You can set the time that the device will compare the actual- and set-
temperature and if necessary does an adaption of the valve position
with this slider.
Offset of the measured
temperature:
You can set an offset temperature for the internal temperature sensor
of the device. That is necessary because eventually the temperature
measured near the radiator can be different than the temperature in
other areas of the room. So you can make sure that the thermostat will
regulate to the right temperature in the room and not just the
temperature near the radiator.
Frost protection:
You can set the temperature that is used for frost protection (7°C per
default).
The frost protection is active if the actual temperature falls below this
temperature. This is independent of other modes of the device and will
always work.
Open window detection:
If this function is activated the device will detect a temperature drop in
the room and switch off the radiator.
sing the slider you can change Using the slider you can change the sensibility (temperature drop within