Technical information
157Eaton RF-System
© 2013 Eaton Electrical Group
a time) of the detection.
Further the time for the heating break can be defined. After this break
the thermostat will continue with the regulation based on its set- and
actual-temperature.
Set value day:
Here you can define the set value for the day or comfort temperature
Set value night:
Here you can define the set value for the night or Standby temperature
Timer programme:
In the timer programme you can define 3 different time areas for every
day. Within this time areas the thermostat will regulate to the day
temperature and outside of this time areas the thermostat will regulate
to the night temperature. Using the Copy-function you can copy the
times of a day to another.
Autonomous – manual –
Set value:
Here you can define the Set value for the manual mode (it has no
influence on the weekly program)
Automatic change of
summer-/winter-time
If this function is activated the device will automatically switch to
summer or winter time on the respective dates.
2. Operation with an intelligent device (Room-Manager, Home-Manager…)
In this mode the regulation of the radiator will be controlled by the intelligent device.
Set-temperatures and weekly programs will be defined in the intelligent device. The RF radiator
thermostat is working like an actuator that controls the radiator depending on the set- and
actual-temperature that it receives from the intelligent device.