Technical information

166 Eaton RF-System - Help
© 2013 Eaton Electrical Group
We recommend plugging the jumpers on the Multi-Heating actuator for each channel to „Heating
only“, “Cooling only” or “Heating and Cooling” depending on how you use the channels in the
Room-Manager. That will make sure that all channels are only controlled when their desired
operation type is active.
See also Heating and Cooling with the Room-Manager Connection to a Multi-Heating actuator
Operation with the Home-Manager and other intelligent devices:
In this case every connected channel of the Multi-Heating actuator receives Set- and actual
temperature from its respective datapoint of a Home-Manager or other intelligent device. Each
datapoint can be connected to multiple inputs of the Multi-Heating actuator but each input can only
have one connection.
If an input of the Multi-Heating actuator is used for „Heating only“, „Cooling only“ or „Heating and
Cooling“ needs to be defined in the Configuration program of the Home-Manager or the 3rd Party
program for the intelligent device. Anyhow you need to make sure that the Multi-Heating actuator
and the control program in the intelligent device work in the same operation type at all time. This is
done by connecting a datapoint of the used device with the „Heating/Cooling“ input of the
Multi-Heating actuator. Every time the control program toggles between heating and cooling the
datapoint needs to send this information to the Multi-Heating actuator.