Technical information

181Eaton RF-System
© 2013 Eaton Electrical Group
Structure of the new extended Status-message:
The extended Status message includes the following information and possible values:
- Device type: Switching actuator
- Device variant: 0, 1, 3, 4, 5, 7 see Switching actuator 10A/16A - General
- Output State: OFF, ON, OFF Locked, ON Locked, BLINKING, OFF Overtemperature
- Status binary input (if available): ON, OFF, Pressed, not pressed, unknown
- Internal temperature: 0-125°C
- actual active Power (if available): x.xW (max. 0-3700W)
- Load error (if available): OK, Not OK
If the option ‚Send Status-Message after a state changes is activated the extended
Status-message will be sent automatically every time the ‚Output State changes. Changes to other
information will not trigger the sending (expectation is the power value if the specific option is
activated see Switching actuator 10A/16A Energy measurement). Actuators with energy
measurement will send their status slightly delayed for around 2 seconds in order to wait for a valid
power measurement.
Which of this information is displayed on the intelligent device depends on the type of the
intelligent device and 3rd Party application it uses.
Speciality for group functions:
If the Switching actuator is controlled by a sensor that controls a big group of new actuators the