Technical information
228 Eaton RF-System - Help
© 2013 Eaton Electrical Group
they want to use the software update function. The USB-RF-Sticks need a specific driver during
the update process. This driver can only be installed if the MRF-software has administrator rights.
If it has just normal user rights the error message „Driver installation failed (5)“ will be shown in the
update window right after the start of the software update function.
You can run the Eaton RF-System as administrator in 2 different ways:
1. Run only once as Administrator
Right click on the shortcut of the Eaton RF-System and select the option „Run as Administrator“.
2. Always run as Administrator
Right click on the shortcut of the Eaton RF-System and select the option „Properties“.
Select the tab „Compatibility“, Activate the option „Run this program as an Administrator“ and click
the OK button.
The Eaton RF-System will now always be started with administrator rights.
Digital Driver Signature:
Depending on the configuration of your windows installation the following window may pop up after
executing the software update function.