Technical information

52 Eaton RF-System - Help
© 2013 Eaton Electrical Group
Show all Connections
Displays all the connections or assignments of all devices carried out in the Connection Mode as a
black connecting line.
Connections you selected before can be deleted or recalculated at any time by right-clicking the
assignment you want. In this case only this particular connection will be deleted or recalculated.
Should you wish to see the assignments of a particular device, you can display the connections of
this particular xComfort device by opening the Drop Down Menu of this device with the right
mouse-button and by selecting the item Connections.
Shortcuts
Keyboard: F7
To display the connections of individual devices, please use the Drop Down menu.
Status-Verbindungen:
In this view all status connections of the project will be displayed.
A status connection is a back channel from an actuator that will send information about the output
status back to a connected intelligent device.
There are two different types of status connections:
- Old Status connections
- New Status connection/extended Status message
Old Status message:
General Information:
The old status message will be sent when an output status of any actuator of the old generation
changes (Switching actuator, Dimming actuator, Shutter actuator, Analog actuator). This old status
message will be sent to the first intelligent device in the actuator sensor list and cannot be routed
and is also not repeated by the actuator.
In earlier MRF versions the old Status message has only been sent by an actuator that was
connected to an intelligent device if there was at least a reception quality >0% between the two
devices (defined by the connection calculation in the MRF). Therefore it could have been possible
that actuators that were switched by an intelligent device by routing never sent their status back.
Since Version 2.30 the sending of the Status of an old actuator can be activated independent of
the reception quality using the option Send old Status message in the configuration window of
each actuator. If deactivated the status message will not be sent like in earlier version when there
was no reception quality between the devices. When activated the status message will always be
sent. Per default this option is activated. The reason for this change is that new generation
actuators and Routers can resend the old status message and forward it to intelligent device if
there is no direct connection possible. The calculation of this special resend can be done either by
using the function ‚Calculate all connections, using the general function ‚Recalculate resenders of
old status connections or right clicking a single status connection and selecting the option
‚Recalculate resenders of old status connections.
Display of old Status connection:
Selecting View -> Status connections will display all old Status-connections in dark turquois color