Technical information

58 Eaton RF-System - Help
© 2013 Eaton Electrical Group
5. In this box (bottom right) you can pre-set the behaviour of the transmitter in case of power
recovery and low battery.
In case the sensor battery is low, you can select whether or not the switching actuator should send
a warning after switching it on (output blinks once).
Regarding power recovery, you can pre-set how the switching actuator should react to it. There are
three options to choose from:
Old value (Standard): Actuator maintains the same state as before the power
failure
On: After power recovery the actuator switches the output ON
Off: After power recovery the actuator switches the output OFF
All functions of the Switching Actuator:
On / Off (Standard)
, occupies 2 command buttons
Switches ON resp. OFF
On / Switch-on Delay
, occupies 1 command button
On Command which is executed immediately or after an adjustable Delay time
Off / On with Switch-off Delay
, occupies 1 command button
Off Command which is executed immediately or after an adjustable Delay time
Off with Advance Warning
, occupies 1 command button
Staircase function which switches ON immediately and switches OFF after an adjustable
time.
The Switching Actuators Output is blinking 15 seconds before it switches OFF.
Push-button/Key Mode
, occupies 2 command buttons
The Switching Actuator is only ON while its sensor is activated; Otherwise it is OFF
Surge
, occupies 1 command button
The Switching Actuator toggles with every sensor activation its output Value.
Blinking
, occupies 1 command button
The Switching Actuator begins to blink when its sensor is activated. You can adjust the
interval time.
No Function
, occupies 1 command button
Has no Function
Functions for Push-button, Hand-held Transmitter, Home Manager and Binary Input Bat/230 Mode
4:
On / Off (Standard)
ON / OFF, and free, only for selectable
On / Switch-on Delay
free selectable for , , and
Off / Switch-off Delay
free selectable for , , and
Off with Advance Warning
free selectable for , , and
Push-button/Key Mode
for
, or , ; only for oder selectable
Surge
only for and selectable
Blinking
free selectable for , , and
Functions for Binary Input Bat/230 Mode 1 and Mode 3 (Pushbutton):
Surge (Standard)
only for selectable
On / Switch-on Delay
free selectable for and
Off / Switch-off Delay
free selectable for and
Off with Advance Warning
free selectable for and
Push-button/Key Mode
for and , only for selectable
Blinking
free selectable for and
Functions for Binary Input Bat/230 Mode 2 and Mode 3 (Switch):
On / Off (Standard)
ON / OFF, only for selectable
On / Switch-on Delay
free selectable for and