Technical information
65Eaton RF-System
© 2013 Eaton Electrical Group
All functions of a shutter actuator:
Shutter (Standard)
, occupies 4 command buttons
Slat up/down resp. Stop and Open/Close for the length of the configured Runtime
Roller Blind
, occupies 4 command buttons
Stop and Open/Close for the length of the configured Runtime
Roller Blind + Open
, occupies 4 command buttons
Stop und Open/Close (with Open briefly) for the length of the configured Runtime
Open
, occupies 1 command button
Open for the length of the configured Runtime
Close
, occupies 1 command button
Close for the length of the configured Runtime
Stop
, occupies 1 command button
Stop Command
Sequencer
, occupies 1 command button
Toggles with every Command in the following sequence Open
–
Stop
–
Close
–
Stop
–
Open …
No Function
, occupies 1 command button
Has no function
Available for CJAU-01/02:
Safety function when ON
, needs 2 command buttons
When safety is activated the actuator moves in safety position and is locked for further
operation
until safety is deactivated from the same sensor or the acknowledge sensor.
Safety function when OFF
, needs 2 command buttons
Like Safety function when ON only vice versa
Acknowledge safety function
, needs 1 command button