Multi-Heating actuator
will be supported, a new mains supplied device that can be used to
control electrical radiator valves
USB-RF-Configuration-Stick is supported, its the successor of the old RS232
configuration interface
USB-RF-Communication-Stick is supported, it has similar functionality as the old
USB-Communication interface
It is now possible to set Transmit- and Receive-performance of the new
USB-RF-Configuration-Stick in the options window
Room-Manager Software Version V40 is supported, this version is necessary to be able to
work with the new Multi-Heating actuator
Replace device: The old USB-Communication interface can now be replaced by the
Ethernet CI or the new USB-RF-Communication-Stick (this does not work backwards)
Connection „Send time and date when changing from X to Room-Manager“ now possible
for Home-Manager, USB-RF-Communication-Stick, USB-Communication-Interface and Ethernet
CI
Window contacts and humidity sensor can now be connected to Room-Manager rooms
even if the room temperature is measured by a RF Radiator thermostat and Room-temperature of
that rooms can be used as variable for logic functions.
Deleting a connection of a group function will now set all remaining connections of that
group to „uncalculated“ instead of recalculating them (only if “Behavior when drawing connections”
is set to „Do not calculate, draw immediately“)
Room-Manager connections Actual values Room 1, Room temperature 1-6, Outdoor
temperature and Room humidity 1-6 now possible for Home-Manager,
USB-RF-Communication-Stick, USB-Communication-Interface and Ethernet CI
Room-Manager outputs can now be connected to Shutter actuators (Attention! Only ON
and OFF commands are sent, Settings need to be changed in the shutter actuator configuration
window)
After every scanning process the MRF will check if newly scanned devices have
connections to existing ones. If thats the case these connections will only be drawn if the already
existing devices have valid entries for the connections. If not the connections will be automatically
deleted.
When copying a group of devices the switching function will now be correctly inserted
instead of using the standard configuration.
Replace device and Transfer virtual device functions will now correctly work for RF
radiator thermostats that already have connections to other devices
When scanning the reception quality it is no longer possible to cancel the process
prematurely if unknown password protected sensors are activated
When loading changes to selected devices or to devices of an area it is now possible to
toggle between mains and battery supplied devices
Whats new for 2.05:
RF Radiator Thermostat is supported, a new battery supplied radiator thermostat that is
used to regulate the Room temperature in combination with a Radiator
Ethernet CI is supported, a new device that connects the xComfort RF solution with the
Ethernet and adds various new functions and possibilities