Technical Data
Effective October 2014
Decorator AL series dimmer
Compliances, specifications and availability are subject to change without notice.
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
Certifications & Compliances
KEY:
cULus NOM
Catalog No.
DAL06P
DCK1
Compliances, specifications and availability are subject to change without notice.
Table 8. Maximum Fluorescent Lamp Wattage
The following table lists the maximum number of Mark 10
®
or AmbiStar
®
ballasts that can be connected to a dimmer for single and multi-
device installations in a wallbox.
Max # of Ballasts per Dimmer for Multiganging
Ballast Cast# Lamp Type # of Lamps Lamp Watts One Gang Two Gang Three Gange
REB-2S26 CFQ26W/G24q 1 26 20 18 16
REB-2S26 CFQ26W/G24q 2 26 10 9 8
REB-2S26 CFTR32W/GX24q 1 32 15 14 12
REB-2S26 CFTR42W/GX24q 1 42 11 10 9
REZ-1Q18 CFQ18W/G24q 1 18 26 23 21
REZ-1Q18 CFTR18W/GX24q 1 18 26 23 21
REZ-2Q18 CFQ18W/G24q 2 18 13 11 10
REZ-2Q18 CFTR18W/GX24q 2 18 13 11 10
REZ-2Q26 CFQ26W/G24q 2 26 9 8 8
REZ-2Q26 CFTR26W/GX24q 2 26 9 8 8
REZ-1T42 CFQ26W/G24q 1 26 18 16 14
REZ-1T42 CFTR26W/GX24q 1 26 18 16 14
REZ-1T42 CFTR32W/GX24q 1 32 14 13 12
REZ-1T42 CFTR42W/GX24q 1 42 11 10 9
REZ-2T42 CFTR32W/GX24q 2 32 7 6 6
REZ-2T42 CFTR42W/GX24q 2 42 5 5 4
REZ-2T42 CFTR57W/GX24q 1 57 8 7 7
REZ-2T42 CFTR70W/GX24q 1 70 7 6 5
IEZ-2S24 FT24W/2G11 2 24/27 9 8 8
IEZ-2S24 F24T5/HO 2 24 9 8 8
REZ-1TTS40 FT36W/2G11 1 36/39 14 13 12
REZ-1TTS40 FT40W/2G11/RS 1 40 14 13 12
REZ-2TTS40 FT36W/2G12 2 36/40 7 6 6
REZ-2TTS40 FT40W/2G11/RS 2 41 6 6 5
REZ-154 F54T5/HO 1 54 8 8 7
REZ-154 FC12T5/HO 1 55 9 8 7
REZ-154 FT55W/2G11 1 55 9 8 7
REZ-2S54 F54T5/HO 2 54 4 4 3
REZ-2S54 FC12T5/HO 2 55 4 4 4
REZ-2S54 FT55W/2G12 2 55 4 4 4
REZ-132 F17T8, FBO16T8 1 17 23 21 19
REZ-132 F25T8, FBO24T8 1 25 18 16 14
REZ-132 F32T8, FBO31T8 1 32 16 14 13
REZ-2S32 F17T8, FBO16T9 2 17 14 13 12
REZ-2S32 F25T8, FBO24T9 2 25 10 9 8
REZ-2S32 F32T8, FBO31T9 2 32 8 7 6
REZ-3S32 F17T8, FBO16T10 3 17 10 9 8
REZ-3S32 F25T8, FBO24T10 3 25 7 6 5
REZ-3S32 F32T8, FBO31T10 3 32 5 4 4
Lutron Tu-Wire® ballast. The total of all line currents for the ballasts connected to the dimmer should be less than: 4-70A for one gang; 4-30A for two gang and 3-90A for three
gang installations.