Electrical Sector Solutions Volume 15: Solar Inverters and Electrical Balance of System
Model Number Model Number Model Number Product line Product name Residential solar solutions Model Number Model Number Model Number Model Number Model Number Model Number A D B Electrical Balance of System for C Residential Installations Our roots in the electrical business run deep. Eaton is a global technology leader in electrical components and systems for power quality, distribution and control.
Electrical Balance of System for Residential Installations DC combiners and switches (600 Vdc) A Solar inverters (600 Vdc) B AC meter breakers, load centers and switches C Eaton’s solutions for protecting and switching DC current are designed and tested to meet UL1741, UL98 and UL98B requirements for solar electrical balance of system equipment. Eaton’s solar inverters use the same robust, reliable technology we put in our uninterruptible power systems (UPS).
Commercial solar solutions E A A F B A C C D Electrical Balance of System for Commercial Installations As your single-source supplier for a solar balance of system package, Eaton can help you build a solar system tailored to the needs of a retail, commercial or institutional site with a focus on: • Reliability • Efficiency • Safety We know space is always at a premium. That’s why we offer totally integrated power control and management solutions like inverters and solar switchboards.
Electrical Balance of System for Commercial Installations A DC combiners, switches and switched combiners (600 Vdc) DC disconnect switches DC circuit breakers DC switched combiners DC switchboards B Solar inverters (600 Vdc) and solar transformers C AC switchgear AC switchboards Commercial-scale solar inverters – 250kW through 500kW Medium voltage step-up transformer AC disconnect switches © 2010 Photo courtesy of Cooper Power Systems C D AC switchgear AC circuit breakers Medium voltage AC
Utility solar solutions B A C D E Electrical Balance of System for Utility Installations Our roots in the electrical industry run deep. As a bankable partner with 100 years of innovation, we are your single source supplier of electrical balance of system solutions to help improve: • Reliability • Efficiency • Safety Eaton provides complete electrical balance of system solutions from the combiners, to the inverter, to the medium voltage interconnection to the grid.
Electrical Balance of System for Utility Installations A DC combiners, switches and switched combiners (1000 Vdc) DC disconnect switches DC circuit breakers Switched combiners DC switchboards B Solar inverters (1000 Vdc) and solar transformers CC1 AC switchgear AC switchboards Utility-scale solar inverters – 250kW through 500kW Medium voltage step-up transformer AC disconnect switches © 2010 Photo courtesy of Cooper Power Systems C D AC switchgear AC circuit breakers Medium voltage AC switc
Services and support Commercial and Utility Electrical Solar Services Eaton’s Electrical Services and Systems engineers can help manage the power of the sun. We offer the convenience of turnkey project teams who can design, build and support your solar power system. Design Support Pre-installation services Post-installation services Eaton’s Electrical Services and Systems (EESS) team can help you choose a solar system that makes technical and financial sense.
Design • Solar site assessments including technical and financial analysis • Solar system design including shading and annual kWh output analysis • Photovoltaic panel design • Electrical balance of system design • Monitoring system design (meters and software) • Building connection and substation design • Turnkey construction project management, including design and procurement services Build • Turnkey construction projects • Photovoltaic panel installation • Electrical balance of system
Volume 15—Solar Inverters and Electrical Balance of System Tab 1—Residential and Light Commercial . . . . . . . . . V15-T1-1 Eaton Grid-Tied Solar Inverter (3.8–7 kW) Tab 2—Commercial and Utility . . . . . . . . . . . . . . . . . . . V15-T2-1 Tab 3—Solar OEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V15-T3-1 Tab 4—AC Power Distribution . . . . . . . . . . . . . . . . . . . V15-T4-1 Appendix 1—Eaton Terms & Conditions . . . . . . . . . . . V15-A1-1 Appendix 2—Catalog Parent Number Index . .
Copyright Dimensions, Weights and Ratings Dimensions, weights and ratings given in this catalog are approximate and should not be used for construction purposes. Drawings containing exact dimensions are available upon request. All listed product specifications and ratings are subject to change without notice. Photographs are representative of production units. Terms and Conditions All prices and discounts are subject to change without notice.
Introduction Eaton is a global leader in power distribution, power quality, control and automation, and monitoring products. At Eaton, we believe a reliable, efficient and safe power system is the foundation of every successful enterprise. Through innovative technologies, cutting-edge products and our highly skilled services team, we empower businesses around the world to achieve a powerful advantage.
Introduction Icons Green Leaf Eaton Green Solutions are products, systems or solutions that represent Eaton benchmarks for environmental performance. The green leaf symbol is our promise that the solution has been reviewed and documented as offering exceptional, industry-leading environmental benefits to customers, consumers and our communities.
Residential and Light Commercial 1.1 Eaton Grid-Tied Solar Inverter (3.8–7 kW) Eaton Grid-Tied Solar Inverter (3.8–7 kW) Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 1 Eaton Grid-Tied Solar Inverter (3.8–7 kW) Contents Eaton Grid-Tied Solar Inverter (3.8–7 kW) Description 1 Page Eaton Grid-Tied Solar Inverter (3.8–7 kW) Product Selection/Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . 1 V15-T1-3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Product Overview Features and Benefits The Eaton Grid-Tied Solar Inverter’s breakthrough technology and features deliver maximum return on investment for consumers.
1.1 Eaton Grid-Tied Solar Inverter (3.8–7 kW) Product Selection/Technical Data and Specifications 1 Eaton Grid-Tied Solar Inverter (3.
1.2 1 Solar Power Center Loadcenters and Meter Breakers Solar Power Center Loadcenters and Meter Breakers Contents Description 1 Solar Power Center Loadcenters and Meter Breakers Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Additional Information . . . . . . . . . . . . . . . . . . .
Solar Power Center Loadcenters and Meter Breakers 1.2 Application Description 1 How to Size a Solar-Ready Loadcenter or a Meter Breaker for your Solar Application The National Electrical Code (2008) Section 690.64(B)(2)/ (2011) Section 705.12(D)(2) states: “The sum of the ampere ratings of overcurrent devices in circuits supplying power to a busbar or conductor shall not exceed 120 percent of the rating of the busbar or conductor.
1.
1.2 Solar Power Center Loadcenters and Meter Breakers Product Selection 1 Solar Power Center Meter Breakers 1 Type CH Meter Breakers Max. Number of 3/4-Inch Spaces Main Breaker (A) Max. Number of Circuits Bus Rating (A) Max.
1.2 Solar Power Center Loadcenters and Meter Breakers 1 Contact the Eaton Flex Center (1-800-330-6479 or flexcenterlincoln@eaton.com) for additional solar features including different device availability, main breaker, bus and solar input ratings. 1 Additional Information CMBE4242PV200BF Loadcenter and accessories—reference Volume 1—Residential and Light Commercial, CA08100002E, Tab 1.
Residential Electric Vehicle Charging Charging Stations 1.3 Contents Charging Stations Description Charging Stations Product Overview . . . . . . . . . . . . . . . . . . . . . . Level 1 Universal Receptacle . . . . . . . . . . . . . . . . Level 1 Charging Station . . . . . . . . . . . . . . . . . . . . Level 2 Charging Station . . . . . . . . . . . . . . . . . . . . Electric Vehicle Simulator . . . . . . . . . . . . . . . . . . . Electric Vehicle Charging Station Pedestal . . . . . .
1.3 Residential Electric Vehicle Charging Charging Stations 1 Product Overview 1 Vehicle Chargers 1 1 1 1 1 1 1 Level 1 Universal Receptacle Description Level 1 Charging Station Level 2 Charging Station Electric Vehicle Simulator Input voltage 110/120 Vac 110/120 Vac 208/240 Vac — Input amperage 16A 16A or 30A — 1 20A, 40A or 80A (1–4 vehicles) Max power 1.9 kW (L116 style) 3.8 kW (L216 style) 7.2 kW (L230 style) — 1 Up to 1.
Residential Electric Vehicle Charging Level 1 Universal Receptacle 1.3 Contents Level 1 Universal Receptacle Description Page Charging Stations . . . . . . . . . . . . . . . . . . . . . . . . . Level 1 Universal Receptacle Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Level 1 Charging Station . . . . . . . . . . . . . . . . . . . . Level 2 Charging Station . . . . .
1.3 1 1 Residential Electric Vehicle Charging Level 1 Universal Receptacle Product Selection Dimensions Approximate Dimensions in Inches (mm) Level 1 Universal Receptacle Level 1 Universal Receptacle Pedestal Description 1 Input voltage 110/120 Vac Input amperage 20A, 40A or 80A (1–4 vehicles) Max power Up to 1.
Residential Electric Vehicle Charging Level 1 Charging Station 1.3 Contents Level 1 Charging Station Description Page Charging Stations . . . . . . . . . . . . . . . . . . . . . . . . . Level 1 Universal Receptacle . . . . . . . . . . . . . . . . Level 1 Charging Station Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . .
1.
Residential Electric Vehicle Charging Level 1 Charging Station 1.3 Dimensions 1 Approximate Dimensions in Inches (mm) (Advanced cord management) 1 Level 1 Charging Station 1 5.34 (135.6) 15.20 (386.1) 1 2.50 (63.5) 1 10.07 (255.8) 1 3.00 (76.2) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—April 2014 eaton.
1.3 1 Residential Electric Vehicle Charging Level 2 Charging Station Contents Level 2 Charging Station Description 1 Page Charging Stations . . . . . . . . . . . . . . . . . . . . . . . . . Level 1 Universal Receptacle . . . . . . . . . . . . . . . . Level 1 Charging Station . . . . . . . . . . . . . . . . . . . . Level 2 Charging Station Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . .
Residential Electric Vehicle Charging Level 2 Charging Station 1.
1.3 1 1 1 1 Residential Electric Vehicle Charging Level 2 Charging Station Dimensions Approximate Dimensions in Inches (mm) (Advanced cord management) Level 2 Charging Station 5.34 (135.6) 15.20 (386.1) 1 2.50 (63.5) 10.07 (255.8) 1 1 3.00 (76.2) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V15-T1-18 Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—April 2014 eaton.
Residential Electric Vehicle Charging Electric Vehicle Simulator 1.3 Contents Electric Vehicle Simulator Description Charging Stations . . . . . . . . . . . . . . . . . . . . . . . . . Level 1 Universal Receptacle . . . . . . . . . . . . . . . . Level 1 Charging Station . . . . . . . . . . . . . . . . . . . . Level 2 Charging Station . . . . . . . . . . . . . . . . . . . . Electric Vehicle Simulator Catalog Number Selection . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . .
1.3 Residential Electric Vehicle Charging Electric Vehicle Simulator 1 Catalog Number Selection 1 Electric Vehicle Simulator Approximate Dimensions in Inches (mm) 1 Electric Vehicle Simulator EVSE TEST B 1 1 Dimensions Type EVSE = Electric Vehicle Supply Equipment 1 10.62 (269.
Residential Electric Vehicle Charging Electric Vehicle Charging Station Pedestal 1.3 Contents Electric Vehicle Charging Station Pedestal Description Page Charging Stations . . . . . . . . . . . . . . . . . . . . . . . . . Level 1 Universal Receptacle . . . . . . . . . . . . . . . . Level 1 Charging Station . . . . . . . . . . . . . . . . . . . . Level 2 Charging Station . . . . . . . . . . . . . . . . . . . . Electric Vehicle Simulator . . . . . . . . . . . . . . . . . . .
1.3 Residential Electric Vehicle Charging Electric Vehicle Charging Station Pedestal 1 Technical Data and Specifications 1 Electric Vehicle Charging Station Pedestal 1 1 1 Dimensions Approximate Dimensions in Inches (mm) Description Specification Electric Vehicle Charging Station Pedestal Description Weight (lbs) Single EVSE—mount pedestal Dual EVSE—mount pedestal 42 lbs Single EVSE pedestal—H x W x D 54.06 (1373.1) x 15.20 (386.1) x 9.70 (246.4) 65 lbs Dual EVSE pedestal—H x W x D 54.
Commercial and Utility Power Xpert Solar 250 kW Inverter 2.1 Power Xpert Solar 250 kW Inverter Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 2.4 2.5 Pow-R-Line C Group-Mounted Distribution Switchboard 2.6 V15-T2-21 V15-T2-23 2 2 2 2 2 V15-T2-25 2 V15-T2-26 2 V15-T2-29 V15-T2-37 V15-T2-41 V15-T2-45 V15-T2-49 V15-T2-59 V15-T2-68 2 2 2 2 2 Solar Services Product Group Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 2 Power Xpert Solar 250 kW Inverter Contents Power Xpert Solar 250 kW Inverter Description 2 Page Power Xpert Solar 250 kW Inverter Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Xpert Solar 250 kW Inverter ● ● DC breakers can be individually turned off, allowing isolation of a defective sub-array while allowing other sub-arrays to operate. This feature enhances de-bugging procedures and maximizes fault-tolerance DC breakers are available on different configurations and ampacity (90A DC, 100A DC, 125A DC, 150A DC, 175A DC, 200A DC and 225A DC) Inverter grounding bus on DC and AC sides allows installation as per NEC 690.
2.1 2 2 2 2 Power Xpert Solar 250 kW Inverter Catalog Number Selection The catalog number is what determines the exact product feature set. The base configuration and subsequent catalog number of the Power Xpert Solar 250 kW Inverter is SOX23111B1092M0011.
2.
2.
2.1 Power Xpert Solar 250 kW Inverter Dimensions 2 Approximate Dimensions in inches (mm) 2 Power Xpert Solar 250 kW Inverter Dimensions and Connection Diagrams 2 X6 ø 2.00 (50.8) Lifting Holes 2 84.25 (2140.0) 18.06 (458.7) 42.13 (1070.1) 2 2 2 Front ISO View Inv. Unit Only 93.58 (2376.9) 90.05 (2287.3) 2 2 2 2 Front ISO View with Transformer 2 2 2 6.00 (152.4) Fork Lift Pockets 45.42 (1153.7) 2 30.00 (762.0) 2 Top View Minimum Clearance to Wall 97.25 (2470.2) 2 8.
2.2 2 Power Xpert Solar 1500/1670 kW Inverter Contents Power Xpert Solar 1500/1670 kW Inverter Description 2 Page Power Xpert Solar 1500/1670 kW Inverter Features and Benefits . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Xpert Solar 1500/1670 kW Inverter Features and Benefits ● ● ● ● ● True MW scale inverter allows for maximum cost savings on installation of inverter and transformer. It also enables a skidless solution as there is only one inverter and a simple pad-mount transformer to be installed Inverter can be configured as a 1.5 MW or 1.67 MW for maximum output power optimization. Depending on the MPPT range for the array, the inverter output power can be set to 1.5 MW or 1.
2.2 2 2 2 2 2 2 Power Xpert Solar 1500/1670 kW Inverter Catalog Number Selection The catalog number system is what determines the product configuration. The base configuration and subsequent catalog number of the Power Xpert Solar 1500/1670 kW Inverter is SOX66T1010000000.
Power Xpert Solar 1500/1670 kW Inverter 2.
2.
DC Disconnects 600 Vdc Single-Pole Disconnects 2.3 Contents 600 Vdc Single-Pole Disconnect Description Page 600 Vdc Single-Pole Disconnects Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 DC Disconnects 600 Vdc Single-Pole Disconnects 2 Features 2 Standard Features ● All switches are single-pole and suitable for switching one circuit ● Clear polycarbonate deadfront to guard against accidental contact with live parts ● NEC 690.17–compliant labeling warning that the switch terminals may be energized in the open position ● NEC 690.14.
DC Disconnects 600 Vdc Single-Pole Disconnects 2.3 Dimensions 2 Approximate Dimensions in Inches (mm) Type 3R Solar Switch 2 Type 12-3R and 4X Solar Switch 2 2 2 B 2 C C B 2 2 2 2 2 A 2 A 2 2 2 2 2 2 Type 3R Solar Switch Ampere Rating A B C Main Lug Capacity 1 Ground Lug Capacity 30 16.35 (415.3) 8.87 (225.3) 9.89 (251.2) #2 AWG–#14 AWG Cu/Al #4 AWG–#14 AWG Cu/Al 60 16.35 (415.3) 8.87 (225.3) 9.89 (251.2) #2 AWG–#14 AWG Cu/Al #4 AWG–#14 AWG Cu/Al 100 22.15 (562.6) 11.
2.3 2 DC Disconnects 600 Vdc Per Pole and 1000 Vdc Disconnects Contents 600 Vdc Per Pole and 1000 Vdc Disconnect Description 2 Page 600 Vdc Per Pole and 1000 Vdc Disconnects Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC Disconnects 600 Vdc Per Pole and 1000 Vdc Disconnects Features 2.3 Standards and Certifications 600 Vdc Specific Features ● First UL Listed 600 Vdc per pole, bi-directional solution in the market ● 2-, 3-, 4- and 6-circuit configurations for grounded systems ● 1-, 2- and 3-circuit configurations for ungrounded systems ● Fusible and non-fusible ● Grounded configurations include isolated return terminals.
2.
DC Disconnects 600 Vdc Per Pole and 1000 Vdc Disconnects 2.3 Dimensions 2 Approximate Dimensions in Inches (mm) NEMA Type 3R 2 NEMA Type 4, 4X Stainless 2 C B 2 2 2 2 A 2 A 2 2 2 2 2 2 600 Vdc Non-Fusible and Fusible Ampere Rating 2 Number of Circuits NEMA Type 3R 1 A B C D A NEMA Types 4, 4X Stainless 1 B C D 3 16.27 (413.3) 8.87 (225.3) 9.89 (251.2) 5.25 (133.4) 19.08 (484.6) 8.76 (222.5) 10.22 (259.6) 5.50 (139.7) 2 Grounded 30, 60 30, 60 6 19.08 (484.6) 12.88 (327.
2.3 DC Disconnects 600 Vdc Per Pole and 1000 Vdc Disconnects 2 Approximate Dimensions in Inches (mm) 2 1000 Vdc Non-Fusible (Fusible Available at 200A and 400A) 2 Number of Circuits NEMA Type 3R 1 A B C 30, 60 1 16.27 (413.3) 8.87 (225.3) 9.89 (251.2) 5.25 (133.4) 30, 60 2 19.08 (484.6) 12.88 (327.2) 10.22 (259.6) 5.50 (139.7) 2 100 1 21.99 (558.5) 11.84 (300.7) 9.89 (251.2) 5.25 (133.4) 2 100 2 24.95 (633.7) 16.13 (409.7) 10.22 (259.6) 200 1 35.38 (898.7) 16.95 (430.
Switchboards—Solar Applications Group Mounted Switchboards Pow-R-Line C Group-Mounted Distribution Switchboard 2.4 Contents Description Page Pow-R-Line C Distribution Switchboards Integrated Facility Switchboard . . . . . . . . . . . .
2.4 Switchboards—Solar Applications Group Mounted Switchboards Standards and Certifications 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 ● Standard Switchboard Height Standard Pow-R-Line C switchboard height is 90 inches (2286.0 mm). Group Mounting Group-mounted circuit protective devices are an assembly of units mounted on a panelboard type base (panelboard construction). Units may be molded case breakers, or FDPW fusible switches. Circuit protective devices are accessible from the front.
Switchboards—Solar Applications Integrated Facility Switchboards 2.4 Contents Integrated Facility Switchboard Description Page Pow-R-Line C Distribution Switchboards . . . . . . . . Integrated Facility Switchboards Features, Benefits and Functions . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Additional Information . . . . . . . . . . . . . . . . . . .
2.4 Switchboards—Solar Applications Integrated Facility Switchboards 2 Features, Benefits and Functions 2 Front Accessible Integrated Facility Switchboards are front accessible and align at the rear, enabling them to be placed against a wall. Most switchboards align at the front and the rear.
Panelboards—Solar Applications Introduction 2.5 Contents Solar Panelboards Description Page Introduction Product Selection Guide EZ Box and EZ Trim . . . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards . . . . . . . . . . . . . . . . . . Type PRL1a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL2a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL3a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL4 . . . . . . . . . . . . . . . . . . . . . .
2.5 2 Panelboards—Solar Applications EZ Box and EZ Trim Contents Type PRL1a Panelboard Description 2 Page Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide . . . . . . . . . . . . . . . . . EZ Box and EZ Trim Standards and Certifications . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards . . . . . . . . . . . . . . . . . . Type PRL1a . . . . . . . . . . . . . . . . . . . . . . . . . . .
Panelboards—Solar Applications EZ Box and EZ Trim Fast Installation The EZ Trim incorporates a groundbreaking design that installs in seconds, rather than minutes. The standard trim features include door-indoor construction; no exposed hardware and no tools are required for installation. 2.5 Each EZ Trim includes hangers attached on the right side. The bottom trim hanger has a notch in its base.
2.5 2 2 2 2 Panelboards—Solar Applications EZ Box and EZ Trim Product Selection Boxes and Trims Only—Type 1 Types PRL1a, PRL2a and PRL3a (400A Maximum) YS Box LT Trim EZ Box 1 EZ Trim 1 Catalog Number Catalog Number Catalog Number Box Dimensions—Inches (mm) Height Catalog Number 20.00 W x 5.75 D (508.0 W x 146.1 D) 36.00 (914.4) YS2036 LT2036S or F EZB2036R EZT2036S or F 42.00 (1066.8) YS2042 LT2042S or F EZB2042R EZT2042S or F 48.00 (1219.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Contents Pow-R-Line C Panelboards Description Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide. . . . . . . . . . . . . . . . . . EZ Box and EZ Trim . . . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards Type PRL1a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL2a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL3a . . . . . . . . . . . . . . . . . . .
2.5 2 2 2 2 2 Panelboards—Solar Applications Pow-R-Line C Panelboards Application Description Whether providing access for solar systems to inverter inputs or combining outputs from multiple inverters, Eaton’s Pow-R-Line C panelboards are available for customization for any application, including backfeed scenarios.
2.5 Panelboards—Solar Applications Pow-R-Line C Panelboards Sub-Feed Lugs Through-Feed Lugs Sub-feed lugs (see figure below) are one means of interconnecting multi-section panels. The sub-feed (second set of) lugs are mounted directly beside the main lugs. These are required in each section except the last panel in the lineup. The feeder cables are brought into the wiring gutter of the first section and connected to the main lugs.
2.5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Panelboards—Solar Applications Pow-R-Line C Panelboards Ambient Temperatures Special Conditions Harmonic Currents The primary function of an overcurrent device is to protect the conductor and its insulation against overheating. In selecting the size of the devices and conductors, consideration should be given to the ambient temperature surrounding the conductors within and external to the panelboard.
2.
2.
2.5 Panelboards—Solar Applications Pow-R-Line C Panelboards Selection Guide 2 Molded Case Circuit Breaker Ratings 2 Note: Circuit breakers equal or exceed Federal Specification W-C-375b requirements for the particular class associated with each circuit breaker type.
2.5 Panelboards—Solar Applications Pow-R-Line C Panelboards 2 Selection Guide, continued 2 Molded Case Circuit Breaker Ratings, continued Note: Circuit breakers equal or exceed Federal Specification W-C-375b requirements for the particular class associated with each circuit breaker type.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Contents Type PRL1a Description Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide. . . . . . . . . . . . . . . . . . EZ Box and EZ Trim . . . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards . . . . . . . . . . . . . . . . . . Type PRL1a Type PRL2a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL3a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL4 . . .
2.5 2 2 Panelboards—Solar Applications Pow-R-Line C Panelboards Product Selection Type PRL1a PRL1a PRL1a Branch Circuit Breakers Interrupting Rating (kA Sym.) 240 Vac 2 Ampere Rating 2 Main Lug Only 100 — — 2 225 — 400 2 — Breaker Type Ampere Rating Interrupting Rating (kA Sym.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Box Sizing and Selection 2 Approximate Dimensions in Inches (mm) Assembled Circuit Breaker Panelboards and Lighting Controls Box size and box and trim catalog numbers for all standard panelboard types are found on Page V15-T2-40. Instructions 1. Using description of the required panelboard, select the rating and type of main required. 2. Count the total number of branch circuit poles, including provisions, required in the panelboard.
2.5 2 2 2 2 2 Panelboards—Solar Applications Pow-R-Line C Panelboards Approximate Dimensions in Inches (mm) PRL1a Panelboard Sizing Panelboard Types Main Breaker Types and Mounting Position (H) = Horizontal (V) = Vertical Sub-Feed Breaker Types and Mounting Position (H) = Horizontal (V) = Vertical Box Dimensions 1 Maximum No. of Branch Circuits Including Provisions Height Width Depth YS Box LT Trim Catalog Catalog Number Number EZ Box Catalog Number EZ Trim Catalog Number 100A — 15 36.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Contents Type PRL2a Description Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide. . . . . . . . . . . . . . . . . . EZ Box and EZ Trim . . . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards . . . . . . . . . . . . . . . . . . Type PRL1a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL2a Type PRL3a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL4 . . .
2.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Box Sizing and Selection 2 Approximate Dimensions in Inches (mm) Assembled Circuit Breaker Panelboards and Lighting Controls Box size and box and trim catalog numbers for all standard panelboard types are found on Page V15-T2-44. Instructions 1. Using description of the required panelboard, select the rating and type of main required. 2. Count the total number of branch circuit poles, including provisions, required in the panelboard.
2.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Contents Type PRL3a Description Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide. . . . . . . . . . . . . . . . . . EZ Box and EZ Trim . . . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards . . . . . . . . . . . . . . . . . . Type PRL1a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL2a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL3a Type PRL4 . . .
2.
2.
2.5 2 2 2 2 2 2 2 2 Panelboards—Solar Applications Pow-R-Line C Panelboards Box Sizing and Selection Approximate Dimensions in Inches (mm) Panel Layout Instructions 1. Select: a. Required mains (lugs or breaker). b. Neutral where required. c. Branch circuits as required. 2. Layout panel as shown below, using appropriate “X” dimensions. 3. Using total X units (panel height) find box height in inches (mm) and box catalog number from table below.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Contents Type PRL4 Description Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide. . . . . . . . . . . . . . . . . . EZ Box and EZ Trim . . . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards . . . . . . . . . . . . . . . . . . Type PRL1a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL2a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL3a . . . . . . . .
2.
2.
2.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Box Sizing and Selection—PRL4B 2 Approximate Dimensions in Inches (mm) Main Lug Only (MLO), Main Breaker, Neutral, Through-Feed Lug (TFL) and Sub-Feed Lug (SFL) “X” Space Requirements. (For other configurations not shown, refer to Eaton.) * = Space available for branch devices. For device sizing, see Page V15-T2-55. • = Blank means no bus under cover, to meet NEC cable bending space.
2.5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Panelboards—Solar Applications Pow-R-Line C Panelboards Approximate Dimensions in Inches (mm) Panel Layout and Dimensions To determine the dimensions of a given panelboard enclosure, make a layout sketch by fitting together the main, branch and lug modules according to the appropriate tables in the layout guide. Assign “X” units to each module as shown and obtain a total “X” number.
Panelboards—Solar Applications Pow-R-Line C Panelboards 2.5 Layout for Branch and Horizontally Mounted Main Devices Layout—PRL4B Filler 1X Sub Panel 12X 2 Breaker to Fusible Transition, All Widths 2 18 Poles 42 20X Poles 2 100A Max. 2 400 Amp. Maximum Bus Rating 1P 1X 2P 2P 2X 3P 3P 2P 2P 3P 3P 24-Inch (609.6 mm) Wide Box 1P 2 2 2X 2 EDB, EDS, ED, EDH, EDC 3X 2 250A Max. JD, HJD, JDC, HJDDC 9 4X 400A Max. DK, KD, HKD, KDC, HKDDC 9 CKD, CHKD, LHH Load 3X 4X 600A Max.
2.5 2 2 2 Panelboards—Solar Applications Pow-R-Line C Panelboards Box Sizing and Selection—PRL4F Approximate Dimensions in Inches (mm) * = Space available for branch devices. For device sizing, Main Lug (MLO), Main Switch, Neutral, Through-Feed (TFL) and Sub-Feed Lug (SFL) “X” Space Requirements. (For other configurations not shown, refer to Eaton.) see Page V15-T2-58. • = Blank means no bus under cover, to meet NEC cable bending space.
Panelboards—Solar Applications Pow-R-Line C Panelboards Approximate Dimensions in Inches (mm) Panel Layout and Dimensions To determine the dimensions of a given panelboard enclosure, make a layout sketch by fitting together the main, branch and lug modules according to the appropriate tables in the layout guide. Assign “X” units to each module as shown and obtain a total “X” number. The height of the enclosure is related to the total “X” units in the layout as shown in table on right.
2.5 2 Layout for Branch and Horizontally Mounted Main Device—PRL4F Fusible to Breaker Transition Requires 1X Filler 2 2 30A 4X 60A 60A 4X 100A 250V Max. 100A 250V Max. 4X 2 100A 2 2 200A Main or Branch Switch 2 2 1X 30A 2 2 Pow-R-Line C Panelboards 100A 36-inch (914.
2.5 Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications Contents Panelboards and Lighting Controls 2 Description Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide. . . . . . . . . . . . . . . . . . EZ Box and EZ Trim . . . . . . . . . . . . . . . . . . . . . . . . Pow-R-Line C Panelboards . . . . . . . . . . . . . . . . . . Type PRL1a . . . . . . . . . . . . . . . . . . . . . . . . . . . Type PRL2a . . . . . . . . . . . . . . . . . . . .
2.
2.5 Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications 1. Ambient Compensating Breakers For ambient compensating breakers (where available) in lieu of standard breakers, add 10 percent to panelboard branch breaker and to main breaker list prices, if required. (Not UL listed.) 2. Bus Density Main bus ampere rating is determined by UL listed temperature test.
2.5 2 2 2 Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications 8. Copper Lugs Optional copper mechanical main lugs only. (Includes main incoming neutral lug.) 10.
Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications 14. Electronic Trip Units 2.5 18. Increased Dimensions (PRL1a, PRL2a and PRL3a Only) Type 1 Enclosure Only 2 Modification 18 2 Modification 14—Applies to Digitrip 310 and 310+ Trip Units Description K-, L- and M-Frame Circuit Breaker (three-pole only) 2 Increased End Gutters Digitrip RMS310 LS 4 inch (101.6 mm) Top or Bottom Digitrip RMS310 LSI 2 7 inch (177.8 mm) Top or Bottom Digitrip RMS310 LSG 1 2 12 inch (304.
2.5 2 2 Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications 25. Painting and Special Coatings Standard boxes are code-gauge galvanized sheet steel. Standard trims are code-gauge sheet steel with a rust inhibiting phosphatized coating and finished with ANSI-61. 22.
2.5 Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications 29. Shunt Trip for Main or Branch Circuit Breaker and FDPW Switches For tripping device from a remote point. Voltage and frequency must be specified. Wiring to terminal blocks is not included. Standard leads extend 18-inches (457.2 mm) out of device. 32. Sub-Metering IQ Multi-Point Submeter II (PRL4 Only) Microprocessor-based breaker-mounted device to monitor power and energy (kW, kWH, kW demand).
2.5 2 2 Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications Modification 33—Panel Type PRL3a Only. Two Breakers Per Panel—Twin Mounted Interrupting Rating (kA Symmetrical) 36. Through-Feed Lugs (3Ph 4W, 3Ph 3W, 1Ph 3W, 1Ph 2W) Note: 225 amperes maximum on Column Type panels. Not available on service entrance panels with main lugs only (six disconnect rule).
2.5 Panelboards—Solar Applications Types PRL1a, 2a, 3a and 4 Modifications 39. Surge Protective Device (SPD) Type PRL1a, PRL2a and PRL 3a and Panelboards Package includes SPD unit connected to the panelboard bus. Available for all enclosure types. Sizing: PRL1a, PRL2a: Add 7 inches (177.8 mm) to the standard box height. PRL3a: Add 4X for 100–200 kA SPD units. Type PRL4 and Elevator Control Panelboards Package includes SPD unit and integral circuit breaker disconnect (30A) connected to the panel bus. 40.
2.5 2 Panelboards—Solar Applications Regional Manufacturing Facilities Manufacturing Plant Locations 2 • 2 SEATTLE 2 2 • 2 • 2 2 • PHOENIX 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 DALLAS • • • • NEW JERSEY BALTIMORE RALEIGH • ATLANTA • HOUSTON 2 2 • ST. LOUIS • HARTFORD CLEVELAND LOS ANGELES 2 2 • • DENVER SAN FRANCISCO 2 2 • CHICAGO SUMTER ★ • ORLANDO Main Plant Sumter 845 Corporate Circle P.O.
Panelboards—Solar Applications Regional Manufacturing Facilities Satellites Speedy Delivery A unique concept of facilities close to customer locations, assuring fast delivery of standard- and custom-assembled equipment when it’s needed. Highly trained and experienced personnel will manage your order and ensure that you receive ontime delivery of high quality equipment that meets your specifications.
2.6 Solar Services Product Group Overview Contents 2 Description 2 Product Group Overview Solar Renewable Analysis and Consultation . . Solar Design. . . . . . . . . . . . . . . . . . . . . . . . . . . Turnkey Services . . . . . . . . . . . . . . . . . . . . . . . Solar Monitoring . . . . . . . . . . . . . . . . . . . . . . .
Solar Services Solar Renewable Analysis and Consultation 2.6 Contents Description Page Product Group Overview. . . . . . . . . . . . . . . . . . . . Solar Renewable Analysis and Consultation Solar Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Turnkey Services . . . . . . . . . . . . . . . . . . . . . . . . . . Solar Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . .
2.6 Solar Services Solar Design Contents 2 Description 2 Page Product Group Overview . . . . . . . . . . . . . . . . . . . Solar Renewable Analysis and Consultation . . . . . Solar Design Product Description . . . . . . . . . . . . . . . . . . . . . Turnkey Services . . . . . . . . . . . . . . . . . . . . . . . . . . Solar Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . .
Solar Services Solar Design DC Engineering Services One-line diagram of the power system is critical to support the system evaluation and analysis. The one-line diagram shows the identification and ratings of electrical equipment such as: transformers, cables, circuit breakers, protective relays, fuses, switches, current transformers, potential transformers, surge arresters, and so on. ANSI device numbers identify protective relay types.
2.6 2 2 2 2 2 2 2 Solar Services Solar Design Product Description Eaton’s Power System Engineering team is your ally to provide analysis and design for connecting renewable and alternative energy generation to the utility grid. Our experience and North American coverage make Eaton the choice to analyze and design the electrical distribution system and substation for wind and solar farm projects. Our power system engineers bring extensive skills and expertise to power system analysis and design.
Solar Services Turnkey Services 2.6 Contents Description Product Group Overview . . . . . . . . . . . . . . . . . . . . Solar Renewable Analysis and Consultation . . . . . Solar Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Turnkey Services Product Description . . . . . . . . . . . . . . . . . . . . . Solar Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . .
2.6 2 2 2 2 2 Solar Services Turnkey Services Product Description Eaton’s turnkey project capabilities can help you build your solar business without adding staff or assets. With decades of experience in managing electrical power, we know what it takes to design and install a power system that generates clean, reliable power. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 V15-T2-76 Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—September 2015 eaton.
Solar Services Solar Monitoring 2.6 Contents Description Page Product Group Overview . . . . . . . . . . . . . . . . . . . . Solar Renewable Analysis and Consultation . . . . . Solar Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Turnkey Services . . . . . . . . . . . . . . . . . . . . . . . . . . Solar Monitoring Product Description . . . . . . . . . . . . . . . . . . . . .
2.6 2 2 2 2 2 2 2 Product Description ● ● ● ● ● 2 ● 2 ● 2 2 2 2 Solar Monitoring The displayed data can also incorporate a looping background of pictures from the site, graphic overlays of the solar power generation in watts and watt-hours for each inverter.
Solar OEM Direct Current Circuit Breakers 3.1 Direct Current Circuit Breakers Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . .
3.1 3 Direct Current Circuit Breakers Specialty Breakers Contents Direct Current Circuit Breakers Description 3 Direct Current Circuit Breakers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.
3.1 Direct Current Circuit Breakers Specialty Breakers 3 Catalog Number Selection 3 DC Circuit Breaker HFDDC 3 150 W 3 3 3 3 3 3 3 3 EGEDC EGSDC EGHDC HFDDC JGEDC JGSDC JGHDC HJDDC HKDDC LGEDC LGSDC LGHDC HLDDC HMDLDC NBDC PBDC 3 3 3 3 3 3 3 = = = = = = = = = = = = = = = = Frame Series G—E (100A max.) Series G—E (100A max.) Series G—E (100A max.) Series C—F (225A max.) Series G—J (250A max.) Series G—J (250A max.) Series G—J (250A max.) Series C—J (250A max.) Series C—K (400A max.
3.
3.
3.
3.
3.
3.
3.1 Direct Current Circuit Breakers Specialty Breakers DC Breaker Terminal Wire Ranges Breaker Frame Maximum Breaker Ampacity Terminal Body Material Wire Type AWG Wire Range/ Number of Conductors Metric Wire Range mm2 Number of Terminals Included Standard Terminal Catalog Number EGEDC, EGSDC, EGHDC 100 Aluminum Cu/Al 14–1/0 2.5–50 3 3TA125EF HFDDC 20 Steel Cu/Al 14–10 (1) 2.5–4 (1) 3 3T20FB 100 Steel Cu/Al 14–1/0 (1) 2.
3.
Direct Current Circuit Breakers Specialty Breakers 3.1 Jumpers Jumpers must be ordered separately. Priced individually.
3.1 Direct Current Circuit Breakers Specialty Breakers 3 Wiring Diagrams 3 Series Connection Diagrams for DC Application 12 3 250 Vdc Maximum—Two Poles in Series 3 3 3 3 Load 3 3 3 3 Load (A) Suitable for use on ungrounded systems, or grounded systems that have one end of load (A) connected to grounded terminal, opposite poles in series connection. Suitable for use on ungrounded systems only.
Direct Current Circuit Breakers Specialty Breakers 3.1 Dimensions Approximate Dimensions in Inches (mm) 3 DC Breaker Dimensions 3 Frame Number of Poles Width Height 3 Depth EGEDC, EGSDC, EGHDC 3 3.00 (76.2) 5.50 (139.7) 2.99 (75.9) HFDDC 1 1.38 (35.1) 6.00 (152.4) 3.38 (86.0) 2 2.75 (70.0) 6.00 (152.4) 3.38 (86.0) 3 4.13 (105.0) 6.00 (152.4) 3.38 (86.0) 4 5.50 (139.7) 6.00 (152.4) 3.38 (86.0) JGEDC, JGSDC, JGHDC 3 4.13 (104.9) 7.00 (177.8) 3.57 (90.7) HJDDC 2, 3 4.
3.2 3 PVGard Solar Circuit Breakers Specialty Breakers Contents PVGard Solar Photovoltaic Circuit Breakers Description 3 3 3 3 3 600 Vdc Per-Pole 1000 Vdc Poles-in-Series 3 Page PVGard Solar Circuit Breakers—600 Vdc Per-Pole and 1000 Vdc Poles-in-Series Application Description . . . . . . . . . . . . . . . . . . Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . .
PVGard Solar Circuit Breakers Specialty Breakers Application Description Features Photovoltaic (PV) systems convert the energy of the sun into electrical power that is fed directly into the electric grid. PVGard circuit breakers are used to protect the wiring from the modules to the combiner box or inverter from overcurrents, and to provide an isolation mechanism.
3.2 3 3 3 PVGard Solar Circuit Breakers Specialty Breakers Product Selection Catalog number includes breaker frame and trip unit. Order terminals separately. See Page V15-T3-22. For complete internal and external accessories, see accessory section of each frame. JG PVS Frame JG PVS Frame, 250A Maximum, 600 Vdc Per Pole, 1.
PVGard Solar Circuit Breakers Specialty Breakers 3.2 3 Catalog number includes breaker frame and trip unit. Order terminals separately. See Page V15-T3-22.
3.2 PVGard Solar Circuit Breakers Specialty Breakers 3 Accessories 3 Available Accessories ● Auxiliary switch ● Shunt trip ● Electrical operator ● Alarm lockout ● Undervoltage release ● Terminals ● Lock-off devices 3 3 3 3 Factory Modifications—Freeze Testing to –40ºC 4 ● ● ● End cap kits Rotary handle mechanisms Flexible shaft handle mechanisms Optional modifications ● Freeze testing 3 For complete internal and external accessories, see the accessory section of each frame.
PVGard Solar Circuit Breakers Specialty Breakers 3.
3.2 3 3 3 PVGard Solar Circuit Breakers Specialty Breakers PVGard Solar Circuit Breaker Terminal Offering Breaker Frame FD PV Maximum Breaker Ampacity Terminal Body Material Wire Type AWG Wire Range/ Number of Conductors Metric Wire Range mm2 Number of Terminals Included Standard Terminal Catalog Number Comments 50 Steel Cu/Al 14–4 (1) 2.
PVGard Solar Circuit Breakers Specialty Breakers 3.2 Jumpers Jumpers must be ordered separately. Priced individually.
3.
PVGard Solar Circuit Breakers Specialty Breakers 3.2 PVGard 600 Vdc Per-Pole Solar PV Circuit Breakers (100% and 80% Rated Frames) JG PVS 3 KD PVS Number of 600 Vdc circuits 3 3 Maximum voltage rating 600 Vdc 600 Vdc Ampere range 90–250A 100–400A Interrupting capacity at 600 Vdc 1.
3.2 3 PVGard Solar Circuit Breakers Specialty Breakers PVGard 1000 Vdc Solar PV Circuit Breakers (100% and 80% Rated Frames) FD PV KD PV LG PV MDL PV 3 3 Number of poles 4 4 4 3 Maximum voltage rating 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc Maximum current rating 100A 350A 400A 600A 3 Interrupting capacity at 1000 Vdc 3 kA 5 kA 5 kA 7.
PVGard Solar Circuit Breakers Specialty Breakers 3.2 Dimensions Approximate Dimensions in Inches (mm) 3 PVGard Solar Circuit Breakers—600 Vdc Per-Pole 3 3 Frame Number of Circuits in a Frame Width Height Depth JG PVS 3 4.13 (104.9) 7.00 (177.8) 3.44 (87.4) KD PVS 3 5.49 (139.4) 10.13 (257.2) 4.31 (109.6) 3 3 3 PVGard Solar Circuit Breakers—1000 Vdc Poles-in-Series Frame Number of Poles Width Height Depth FD PV 4 5.50 (139.7) 6.00 (152.4) 3.38 (86.0) KD PV 4 7.22 (183.4) 10.
3.2 3 3 3 PVGard Solar Circuit Breakers Specialty Breakers Wiring Diagrams Series Connection Diagrams for DC Application 12 JF PVS, KD PVS—600 Vdc Per-Pole 3 3 3 3 3 3 Load Suitable for grounded or ungrounded systems. Suitable for quantity (3) 600 Vdc circuits.
DC Switch Disconnectors 3.3 Contents DC Switch Disconnectors 3 Description DC Switch Disconnectors Product Selection . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.
DC Switch Disconnectors 3.3 Bridge Kits 3 3 Two-Pole (+ and –) on One Side ● ● ● ● Model contains parts for upper or lower row of switchgear side for fourpole switches N...-S1(S15)DC that are used as two-pole switches for DC ● Each link connects two contacts in series Incoming unit and outgoing at bottom according to the switching diagrams N4-4-... ≥1250A at 65°C alternate connection at bottom through module plates NZM4-4-XKM2S1600 N4-4-...
3.3 DC Switch Disconnectors 3 3 Two-Pole (+ and –) Double Sided 3 3 ● Each link connects three contacts in series ● Incoming unit and outgoing at bottom or top, according to the switching diagrams 3 3 3 3 ● Model contains parts for upper and lower row of switchgear side for fourpole switches N...-S1(S15)DC that are used as two-pole switches for DC 3 3 Bridge Kits Bridge Kits NZM...-XKV...2POU...
DC Switch Disconnectors 3.3 3 3 Single-Pole (+ and –) Double Sided ● ● Each link connects four contacts in series (plus or minus) ● Incoming unit and outgoing at bottom or top, according to the switching diagrams 3 3 3 3 Model contains parts for upper and lower row of switchgear side for fourpole switches N...-S1(S15)DC that are used as singlepole switches for DC 3 3 3 Bridge Kits 3 Bridge Kits NZM...-XKV...1P...
3.3 3 3 3 3 3 DC Switch Disconnectors Technical Data and Specifications Reduction of the rated operating current (derating) at different ambient temperatures, fitting positions, degrees of protection and jumper kits.
3.
3.3 DC Switch Disconnectors 3 Switch Disconnectors 1000 Vdc 3 Description 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 N2-4-...-S1-DC Max. 250A N3-4-...-S1-DC Max. 550A N4-4-...-S1-DC Max.
3.3 DC Switch Disconnectors Dimensions Central Fitting Position IT Network Including the Possibility of a DoubleGround Fault Approximate Dimensions in Inches (mm) 3 Switch Disconnectors, Four-Pole N2-4...DC 3 90˚ 0.98 (25.0) ≥ 3.54 (90.0) 21 0.77 (19.5) 2.76 (70.0) 90˚ M8 x 22 90˚ In ungrounded networks (for example, IT) the installation has to be done in a way to keep the likelihood of a double-ground fault neglectably low.
3.3 DC Switch Disconnectors 3 Approximate Dimensions in Inches (mm) 3 Jumper Kit, NZM2-4-XKV... 0.98 (25.0) 1 3 2 ≥ 3.54 3.27 (90.0) (83.0) 3 3 ≥ 4.72 (120.0) 2 1 3.54 (90.0) 3.27 (83.0) 10.8 (275.0) 9.21 (234.0) 8.50 (216.0) 3 3 ≥ 3.54 (90.0) 1 1.38 (35.0) ≥ 0.20 (5.0) 5.51 (140.0) 3 3 3 ≥ 0.20 (5.0) ≥ 4.72 (120.0) 4.53 (115.0) 3 19.88 (505.0) 3 10.83 (275.0) 3 3 3 3 ≥ 0.20 (5.0) 3.74 (95.0) ≤ 90° M5 x 75 2.74 (69.7) 6.25 (158.8) 1.22 (31.0) 6.38 (162.0) ≥ 4.72 (120.
3.3 DC Switch Disconnectors Approximate Dimensions in Inches (mm) 3 Switch Disconnectors, Four-Pole, N4-4...DC 5.51 (140.0) 2 1.30 (33.0) 3 3.17 (80.5) 9.45 (240.0) 3 NZM4-4-XKV2P-K 7.91 (201.0) 4.25 (108.0) 7.09 (180.0) 8.15 (207.0) 0.31 5.43 1.73 (138.0) (8.0) (44.0) ≥ 3.94 (100.0) 1 Jumper Kit, NZM4-4-XKV2P-K 12.32 (313.0) 3 N 15.79 (401.0) 0.59 (15.0) 0.59 (15.0) 1.77 (45.0) 2.76 (70.0) Ø 0.41 (10.5) 11.02 (280.0) 0.98 (25.0) 3 3 Ø 0.51 (13.0) 3.94 (100.0) 1.26 (32.
3.4 3 DC Switches 600 Vdc and 1000 Vdc Disconnects Contents Description 3 DC Switches 3 3 3 3 3 3 3 3 3 DC Switches 3 Product Description 3 3 3 3 3 3 3 3 3 Eaton’s new offering of PV switches have multiple poles factory-wired, and they are approved for NEC Article 690 applications right from the box. Other manufacturers require the contractor to add jumpers to a two- or threepole switch, add a neutral, and add labels to meet this requirement.
DC Switched Combiners 3.5 Contents DC Switched Combiners 3 Description 3 DC Switched Combiners 3 3 3 3 3 3 3 3 DC Switched Combiners 3 Product Description 3 The Eaton switched combiner (ESC) unites Eaton’s 600 Vdc solar disconnect and sourcecombiner box in one convenient enclosure (1000 Vdc Switched Combiners available late 2012). 3 3 3 3 For more information on Eaton’s DC Switched Combiners, please see Tab 2.5 of this catalog.
3.6 3 Dry-Type Distribution Transformers Encapsulated Transformers Contents Dry-Type Transformer Family Description 3 Encapsulated Transformers Ventilated Transformers/ Open Core-Coil Assemblies . . . . . . . . . . . . . . . . 3 3 3 3 3 3 3 3 3 Encapsulated Transformers 3 Product Description 3 3 3 3 3 3 Eaton’s family of encapsulated transformers is ideally suited for harsh outdoor environments.
Dry-Type Distribution Transformers Ventilated Transformers/Open Core-Coil Assemblies 3.6 Contents Dry-Type Transformer Family Description Encapsulated Transformers . . . . . . . . . . . . . . . . . .
AC Power Distribution Magnum DS Switchgear Eaton offers a full range of AC power distribution products to help you complete your electrical system. This table of contents provides references to other catalogs in our library where you can access selection and technical data for these products.
Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Contents Eaton Terms & Conditions Description Page Terms and Conditions of Sale. . . . . . . . . . . . . . . . . Terms of Payment . . . . . . . . . . . . . . . . . . . . . . . . . Freight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Prices All prices are subject to change without notice. In the event of a price change, the effective date of the change will be the date of the new price or discount sheet, letter or telegram. All quotations made or orders accepted after the effective date will be on the new basis. For existing orders, the price of the unshipped portion of an order will be the price in effect at time of shipment.
Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Freight Warranty Freight policy will be listed on the Product discount sheets, or at option of Seller one of the following freight terms will be quoted. Risk of Loss Risk of loss or damage to the Products shall pass to Buyer at the F.O.B. point. F.O.B.—P/S—Frt./Ppd. and Invoiced Products are sold F.O.B. point of shipment freight prepaid and invoiced to the Buyer. Concealed Damage Except in the event of F.O.B.
Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Extended Warranty for Products If requested by the Buyer and specifically accepted in writing by Seller, the foregoing standard warranty for Products will be extended from the date of shipment for the period and price indicated below: ● ● ● 24 months—2% of Contract Price 30 months—3% of Contract Price 36 months—4% of Contract Price Special Warranty (In and Out) for Products If requested by the Buyer and specifically accepted in writin
Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Returning Products Authorization and shipping instructions for the return of any Products must be obtained from Seller before returning the Products. When return is occasioned due to Seller error, full credit including all transportation charges will be allowed.
Appendix 2—Catalog Parent Number Index A AAL . . . . . . . . . . . KT. . . . . . . . . . . . V15-T3-8 V15-T3-20 AA1 . . . . . . . . . . . V15-T3-20 L ALM . . . . . . . . . . V15-T3-20 LGE . . . . . . . . . . V15-T3-8 AUX . . . . . . . . . . . V15-T3-20 LGH . . . . . . . . . . V15-T3-9 A1L . . . . . . . . . . . V15-T3-20 LGPV . . . . . . . . . V15-T3-18 A1X . . . . . . . . . . . V15-T3-20 LGS . . . . . . . . . . V15-T3-8 A2X . . . . . . . . . . . V15-T3-20 LKD . . . . . . . . . .
Appendix 2—Catalog Parent Number Index Numerics 3TA . . . . . . . . . . . 3TA4 . . . . . . . . . . 3TA6 . . . . . . . . . . 3T2 . . . . . . . . . . . 3T20 . . . . . . . . . . 4TA . . . . . . . . . . . 4T4 . . . . . . . . . . . 4T6 . . . . . . . . . . . V1-A2-2 V15-T3-21 V15-T3-8 V15-T3-8, V15-T3-9 V15-T3-21 V15-T3-11 V15-T3-21 V15-T3-21 V15-T3-21 Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—September 2015 eaton.
Appendix 3—Alphabetical Product Index A E AC Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V15-T4-1 Eaton Grid-Tied Solar Inverter (3.8–7 kW) . . . . . . . . . . . . . . V15-T1-2 AC Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V15-T4-1 Eaton Terms & Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . Freight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Limitation of Liability . . . . . . .
Appendix 3—Alphabetical Product Index N Solar (PV) Systems Interconnect Non-Padlockable Handle Block Molded Case Circuit Breakers, Speciality Breakers, PVGard Solar Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V15-T3-19 Power Xpert Solar 250 kW Inverter . . . . . . . . . . . . . . . V15-T2-2 Solar Power Center Loadcenters and Meter Breakers . . . . V15-T1-4 Solar Services Product Group Overview . . . . . . . . . . . . . . . . . . . . . .