Technical data
April 2008
16-34
For more information visit: www.eaton.com PG03300001E
Accessories & Modification Codes
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Accessories
Lighting Contactors
Type J Auxiliary Contact 
Type J Auxiliary Contact for 
A202/ECL
■ Capable of being field mounted in a 
contactor or starter (Classes A200, 
A900 Sizes 00 – 6, V200, V201 vacuum 
and definite purpose controllers).
■ Provides two separate electrical 
contact sets which wire vertically 
and are color coded; black desig-
nates NC and silver designates NO. 
Please note that the vertical wiring 
is contrary to the horizontal wiring 
of the L-56 auxiliary contacts.
■ Designed to fit within dimensions of 
starter; no additional panel space is 
required.
■ Provides circuit isolation (no polar-
ity restrictions) and single break 
bifurcated contacts.
Table 16-101. Auxiliary Contact Ratings 
Table 16-102. Auxiliary Contact Types 
SS-56 Surge Suppressor
SS-56 Surge Suppressor for 
A202/ECL
■ Designed to be used with magnetic 
motor controllers through Size 4 in 
120V, 60 Hz control circuit applica-
tions where electronic equipment is 
used.
■ Steady State Coil Volts: 120, 60 Hz, 
RMS
■ Peak Input Volts: 169.6, 60 Hz, 
Max. Amplitude
■ Max. Ambient Temperature: 65°C
■ Nominal Limiting Volts: 270 Peak
■ Nominal Rate of Volt Rise: 
.5 per mS
Table 16-103. Surge Suppressor 
Can be used on Sizes 5 and 6 with 120V coil. 
Mounting bracket required — order sepa-
rately. Mounting Bracket 177C043G04.
F-56 Fuse Block for A202/ECL
■ Facilitates installation of fuses (15A, 
600V max.) in control circuits.
■ Utilizes Bussman type KTK fuses, 
or equivalent.
■ Mounts in same cavity as Type J 
auxiliary contact.
■ No tools or mounting hardware 
needed.
■ Fuse not included.
Table 16-104. Fuse Block 
R-56 Interposing Relay for 
A202/ECL
The R-56AA interposing relay is a low 
energy solid-state device with a single 
NO solid-state contact. It can be used as 
a 120V AC control relay, and will oper-
ate on as little as 40V AC input. Is useful 
in applications requiring long control 
wiring runs where excessive voltage 
drop would prevent the contactor or 
relay from energizing. Will operate a 
Size 4 contactor from 10,000 feet using 
18 AWG wire.
Table 16-105. Interposing Relay 
Power Pole Kit for A202/ECL
■ Adds 1NO or 1NC power pole to 
Size 00 – 1 A201 Class contactors.
■ Factory installed or field mountable 
in load side auxiliary cavities.
■ 600V AC.
■ Continuous current rating of 18A for 
Size 0, 27A for Size 1.
Table 16-106. Power Pole Kit 
Do not use with DC operated contactors. 
Voltage Make Break
NEMA A600
120 – 600V AC
72 – 120V AC
28 –  72V AC
7200 VA
60A
60 VA
720 VA
720 VA
10A
NEMA R300
28 – 300V DC 28 VA 28 VA
Contact
Type
Max. Catalog 
Number
1NO and 1NC
2NC
2NO
1 Coil Clearing 
NC and 1NO
4
4
4
4
J11
J02
J20
J1C
Type Mounting Kit Catalog Number
Starter SS-56
Mounting Kit Catalog
Number
Starter
Panel
F56
F56-P
Type 
Mounting
Kit Catalog 
Number
Starter or Panel R56-AA
Continuous
Current
Rating
Kit
Size
Kit
Catalog
Number
Normally Open
18
27
0
1
PNO-0
PNO-1
Normally Closed
18
27
0
1
PNC-0
PNC-1