Technical Bulletin

PROFIBUS-DP External Communication Cards
PowerXL DG1 Series VFD MN040010EN—May 2014 www.eaton.com 79
PROFIBUS-DP External Communication Cards
PowerXL DG1 can be connected to the PROFIBUS
®
DP
using a field bus board. PowerXL DG1 can be controlled,
monitored and programmed from the Host system. The
devices are connected in a bus structure. There is a max of
32 stations (master or slave) can be connected to one
segment bus. The bus is terminated at beginning and end of
each segment. To ensure error-free operation, both bus
terminations must always be powered, if more than
32 stations are used, repeaters are required.
PROFIBUS Specifications
Table 100. PROFIBUS Technical Data
Line length depends on different transmission speeds.
Table 101. Line Length
Items Value
Terminal DB9 connector (Female) or
5.00 mm connector (male)
Data transfer method RS-485 half-duplex
Cable Twisted pair (1 pair and shield)
Isolation 500 Vdc
Protocol PROFIBUS DP-V1
DOIO type ST1 Telegram
Baud rate 9.6K~12M
Addresses 2~126
Environment
Ambient operating temperature –10°C to +55°C
Storing temperature –40°C to +60°C
Humidity <95%, no condensation allowed
Altitude Max. 1000m
Vibration 0.5G at 9–200 Hz
Safety Fulfills EN 50178 standard
Baud rate (kbit/s) 9.6 19.2 93.75 187.5 500 1500 3000–12000
Length line A [m] 1200 1200 1200 1000 400 200 100