Cut Sheet

Volume 8—Sensing Solutions CA08100010E—January 2015 www.eaton.com V8-T1-15
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.
1.2
Safety Products
RS Safety Interlock Switches
RS Safety Interlock Switches
Contents
Description Page
RS Safety Interlock Switches
Catalog Number Selection . . . . . . . . . . . . . . . . V8-T1-16
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T1-16
Recommended Logic Interfaces . . . . . . . . . . . V8-T1-18
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T1-18
Technical Data and Specifications . . . . . . . . . . . V8-T1-19
Mounting Instructions . . . . . . . . . . . . . . . . . . . V8-T1-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T1-21
RS Safety Interlock Switches
Product Description
Eaton’s RS safety interlock
switches have been specifically
designed for monitoring of
protective guards, such as
doors, flaps and hoods. All
switches in this family are
safety-rated and use
magnetically coded actuators
to minimize defeat by simple
magnets. With correct
installation, the RS family
complies with EN ISO 13849-1
and IEC 62061 guidelines.
Operation
The RS safety interlock family
is comprised of three series:
RS2, RS2R and RS4. The
assembly comprises a sensor
component and a separate
magnet actuator component.
The sensor is typically
mounted to a stationary
portion of a structure and the
magnet to a movable portion.
When the sensor and the
actuator are within operating
range, the NC contacts will
be closed and the NO
contacts will be open.
Features
Non-contact actuation
Reversible mounting
High misalignment
tolerance
Up to SIL 3 and up to
PLe ratings
–10 to +55°C temperature
range
IP67
Standards and Certifications
IEC 61508
ISO 13849
EN 1088
cUL
CE
TÜV
Safety Notes
Do not use as a mechanical
stop/shipping brace.
Any change to an original
Eaton safety position
switch is not permitted and
automatically leads to the
loss of all approvals.
Switch must never
be used as a
mechanical stop.
For the most current information