Cut Sheet

V8-T3-78 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3.12
Inductive Proximity Sensors
Nonmetallic Tubular Sensors
Technical Data and Specifications
Nonmetallic Tubular Sensors
Wiring Diagrams
Nonmetallic Tubular Sensors
Dimensions
Approximate Dimensions in Inches (mm)
12 and 18 mm
30 mm
Description Two-Wire AC Models Three-Wire DC Models
Operating voltage 20–250 Vac, 50/60 Hz 10–30 Vdc
Maximum load current 150 mA 200 mA
Switching frequency
12 mm 25 Hz 2000 Hz (shielded); 1000 Hz (unshielded)
18 mm 25 Hz 1000 Hz (shielded); 500 Hz (unshielded)
30 mm 25 Hz 300 Hz (shielded); 150 Hz (unshielded)
Protection Short circuit and reverse polarity
Temperature range –13 to 158 °F (–25 to 70 °C) –13 to 158 °F (–25 to 70 °C)
Enclosure material Polybutylene Teraphtalate (PBT) Polybutylene Teraphtalate (PBT)
Enclosure rating NEMA 3, 3S, 4, 4X, 13 (IP66) NEMA 3, 3S, 4, 4X, 13 (IP66)
Indicator LED Lights when output is ON Lights when output is ON
Operating
Voltage Output Cable Models
Operating
Voltage Output Cable Models
Two-Wire Sensors Three-Wire Sensors
20–250 Vac
50/60 Hz
All 10–30 Vdc NPN
PNP
BU
BN
Load
L1 or +V
L2 or (–)
BU
BN
(–)
+V
BK
Load
BU
BN
(_)
+V
BK
Load
AB
Thread Size
C
12 mm
2.17 (55) 1.77 (45) M12 x 1
18 mm
2.17 (55) 1.77 (45) M18 x 1
AB
Thread Size
C
30 mm
3.15 (80) 2.36 (60) M30 x 1.5