Cut Sheet

Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T7-11
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.
7.3
Current and Voltage Sensors
CurrentWatch ECSJ Series
ECSJ Series CurrentWatch Current Switches
Contents
Description Page
ECSJ Series CurrentWatch Current Switches
Standards and Certifications . . . . . . . . . . . . . . V8-T7-12
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V8-T7-12
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T7-13
Technical Data and Specifications . . . . . . . . . . V8-T7-13
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V8-T7-14
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T7-14
ECSJ Series CurrentWatch Current Switches
Product Description
The CurrentWatch ECSJ
Series current operated
switches from Eaton’s
Electrical Sector provide the
same dependable indication
of status offered by the
CurrentWatch ECS Series,
but with the added benefit of
increased setpoint precision.
A choice of three, jumper-
selectable input ranges
allows the ECSJ Series to be
tailored to an application,
providing more precise
control through improved
setpoint resolution. Self-
powering, isolated solid-state
outputs, 1–6A, 6–40A and
40–200A input ranges, and a
choice of split- or solid-core
enclosures are standard.
For typical applications of the
Current
Watch ECSJ Series,
see listing on this page.
Application Description
Typical Applications
Electronic Proof of
Flow—Current operated
switches eliminate the
need for multiple pipe or
duct penetrations and are
more reliable than electro-
mechanical pressure or
flow switches
Conveyors—Detect jams
and overloads
Lighting Circuits—Easier
to install and more
accurate than photocells
Fans, Pumps and Heating
Elements—Faster
response than temperature
sensors
Critical Motors
Ancillary Equipment
For the most current information
on this product, visit our Web site:
www.eaton.com
Example Application—
Pump Jam and Suction Loss Protection
Features
Choice of NO or NC
Solid-State Outputs
1A at 240 Vac
0.15A at 30 Vdc
15A at 120 Vac
3A at 120 Vac
0.15A at 30 Vdc, dual
contact
Self-Powered—Cuts
installation and operating
costs
Easily Adjustable
Setpoint—Speeds start-up
and reduces inventory
Solid- or Split-Core
Housings—Choose the
appropriate version for your
application
LED Indication—Provides
quick visual indication of
output contact status
Built-In Mounting Feet
Provide for a secure
installation
UL, cUL and CE
Approved—Accepted
worldwide
Jam
AMPS
Overload Setpoint
Current Switch
Motor
Starter
Digital
Input
PLC
B/I Card
Motor
Off
Normal Operation
Time
Motor
Control
Signal