Cut Sheet

V8-T11-6 Volume 8—Sensing Solutions CA08100010E—November 2012 www.eaton.com
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11.1
Legacy Sensor Products
Photoelectric Sensors—Legacy
Technical Data and Specifications
Photoelectric Sensors—Legacy
1356R-6503
1356RD6503
1357A-6513
1357AD6513
1357R-6513
1357RD6513
1357A-6503
1357AD6503
1357R-6503
1357RD6503
1355A-6517
1355AD6517
1355A-6507
1355AD6507
1356A-6517
1356AD6517
1356A-6507
1356AD6507
1357A-6517
1357AD6517
1357A-6507
1357AD6507
1555A-6513
1555AD6513
1555R-6513
1555RD6513
1555A-6503
1555AD6503
1555R-6503
1555RD6503
1555A-6517
1555AD6517
1555A-6507
1555AD6507
1179A-6501
1279A-6501
1170A–300
1270A–300
1173A–300
1273A–300
1173A–100
1273A–100
1173A–200
1273A–200
1470A-6501
1471A-6501
6210A-6501
1370A-6501
9082A-6501
1372A-6501
1571A-6501
6276A-6501
6221A-7501
8170A-6501
8170A-6502
8170A-6504
8170A-6505
8171B-6501
8171B-6502
9072A-6501
8172A-6501
8172A-6502
8771A-6501
8772A-6501
8173A-6507
1480B-6501
1480R-6501
1380B-6501
1381B-6501
1382B-6501
1384B-6501
1383B-6501
1383R-6501
1580B-6501
8880C-6501
8881C-6501
8884C-6501
8884C-6502
8880C-6502
8881C-6502
8882B-6501
8280A-6501
8281A-6501
8282A-6501
Description E58 18 mm Tubular Series E64 Terminal Base Series E65 Miniature Series 11 Series 20 Series
Operating voltage 20–264 Vac
10–30 Vdc
16–240 Vac/dc 10–30 Vdc 115–125 Vac
230 Vac
95–130 Vac
100–125 Vac
200–250 Vac
Output function Light and dark operate
models available
Selectable light or dark
operate
Selectable light or dark
operate
Selectable light or dark
operate
Selectable light or dark
operate
Maximum load current AC: 300 mA
DC:
250 mA (NPN)
100 mA (PNP)
1A at 250 Vac
2A at 30 Vdc
100 mA NPN or PNP Varies by output device
from 5 mA to 10A
Varies by output device
from 5 mA to 10A
Enclosure ratings NEMA 1, 2, 3, 4, 4X, 6,
12 and 13
NEMA 1, 3, 4, 12 and 13
IP66
NEMA 1, 3, 4, 12 and 13
IP66
NEMA 4 and 13 NEMA 3, 4, 6 and 13
Respons
e time range 1 ms to 10 ms 20 ms 330 microseconds to 2 ms 7 ms 1 ms to 30 ms
Description 50 Series 55 Series 60 Series 70 Series 80 Series
Operating voltage 90–132 Vac at 60 Hz
100–132 Vac at 50 Hz
180–264 Vac at 60 Hz
200–264 Vac at 50 Hz
10–30 Vdc
20–264 Vac and 15–30 Vdc
10–30 Vdc
115 Vac
230 Vac
11–15.5 Vdc
Self-contained control units:
115 Vac or
230 Vac versions
Modular control units:
9–18 Vdc
97–130 Vac
204–255 Vac
22–26 Vac
10–30 Vdc
Output function Selectable light or dark
operate
Light and dark operate
models available
Selectable light or dark
operate
Selectable light or dark
operate
Light or dark operate (switch-
selected on control unit)
maximum load current Varies from 50 mA to 2A AC/DC units: 300 mA
DC units:
250 mA (NPN),
100 mA (PNP)
Optional three amp SPDT relay
(AC/DC models)
Varies by output device from
5 mA to 10A
Varies by output device from
5 mA to 10A
Varies by model from
50 mA to 1A
Enclosure ratings NEMA 1, 3, 4, 12 and 13 NEMA 1, 3, 4, 6, 12 and 13 Heads: NEMA 3, 4, 6,
12 and 13
Control Units:
NEMA 12 (enclosed)
NEMA 1 (module)
Varies with control unit or
sensor head selected
NEMA 1, 3, 4, 12 and 13