Cut Sheet

Volume 8—Sensing Solutions CA08100010E—November 2012 www.eaton.com V8-T6-21
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6.2
Conveyor Sensor Systems
200 Series Zero Pressure Accumulation
Technical Data and Specifications
Basic and Progressive Logic Sensors
14266 and 14286 Models
Standard Sensors
14256 Models
Note
1
CAUTION: Will not protect against overloads between 100–300 mA.
Description
Specification
Input voltage 18 to 30 Vdc, reverse polarity protected
Power dissipation 250 mW maximum
Output type NPN or PNP
Current switching capacity 100 mA maximum
OFF-state leakage 10 mA maximum
ON-state voltage drop 2.5V at 100 mA
Slug input NPN: Integral diode isolates slug input; input is protected against mis-wiring and is active
from “0” to a voltage level equal to the current “input voltage” minus 6 volts
PNP: Integral diode isolates slug input; input is protected against mis-wiring and is active from 1–30 Vdc
Response time 8 ms
Connector 5-pin, works with mating plug AMP #104257-4; 2-pin, works with mating plug AMP #104257-1
Temperature range Operating: –25° to 55°C (–13° to 131°F)
Storage: –25° to 70°C (–13° to 158°F)
Material of construction Lens: Polycarbonate; body: Cycoloy and Lexan; connector: glass-filled PCT
Vibration and shock Vibration: 30g over 10 Hz to 2 kHz; shock: 30g for 10 ms 1/2 sinewave pulse
Enclosure ratings NEMA 1
Cable-pull strength 20 pounds (static)
Short-circuit protection The output is protected against dead shorts only.
Operation: Output is continuously retried at 3 ms intervals and will automatically reset when
short is removed (no visual indication of a short-circuit condition).
1
Indicator LED Lights steady when output is ON; OFF when output is OFF; OFF when output is in short-circuit mode
Description
Specification
Input voltage 10 to 30 Vdc, reverse polarity protected
Power dissipation 120 mW maximum
Output type NPN only or NPN and PNP dual output
Output operation–air to brake ON when beam is blocked; OFF when beam is not blocked
Output operation–air to drive ON when beam is not blocked; OFF when beam is blocked
Current switching capacity 100 mA maximum
OFF-state leakage 10 mA maximum
ON-state voltage drop 2.5V at 100 mA
Slug Input Integral diode isolates slug input; input is protected against mis-wiring and is active
from “0” to a voltage level equal to the current “input voltage” minus 6 volts
Response time 8 mS
Connector Works with mating plug; AMP #104257-4
Temperature range Operating: –25° to 55°C (–13° to 131°F)
Storage: –25° to 70°C (–13° to 158°F)
Material of construction Lens: Polycarbonate; body: Cycoloy and Lexan; connector: glass-filled PCT
Vibration and shock Vibration: 30g over 10 Hz to 2 kHz; shock: 30g for 10 ms 1/2 sinewave pulse
Enclosure ratings NEMA 1
Cable-pull strength 20 pounds (static)
Short-circuit protection The output is protected against dead shorts on the NPN output only.
Operation: output is continuously retried at 3 ms intervals and will automatically reset when
short is removed (no visual indication of a short-circuit condition).
1
Indicator LED Lights steady when output is ON; OFF when output is OFF; OFF when output is in short-circuit mode