Cut Sheet

V8-T5-70 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.6
Photoelectric Sensors
Prism Series Sensors
Product Overview
Product Comparison
Eaton’s cost-effective Prism
Series, OEM Prism and
premium Comet Series all
share the same 18 mm flat-
sided housing. This results in
the largest interchangeable
sensor family available,
allowing you to select from
well over 250 different models
to solve the widest variety of
sensing applications.
Comparison
Compared to the similar-
looking Comet, the Prism
Series is optimized for just
value, with a basic feature set
best suited for OEMs:
DC and AC/DC versions
Isolated AC/DC solid-state
outputs
Prism Series
Easy and Flexible Wiring
Prism’s isolated output
simplifies wiring because it
acts like a mechanical relay
contact but with solid-state
speed and reliability. Use the
most convenient available
voltage for the sensor while
switching to a different
voltage with the isolated
contact. NPN or PNP is easily
determined by the way you
wire the output.
Wiring the Prism Series
for Logic
With Prism, you can perform
simple “and/or” logic without
the need for the added cost
of an external controller.
Low leakage (10 μA) and
resistance ratings (25 ohms)
allow Prism sensor outputs to
be wired in series or parallel.
Two common logic examples
are shown at right:
“OR Function
AND” Function
Product Selection
Thru-Beam Sensors
Three-Wire and Four-Wire Sensors
Notes
See listing of compatible connector cables on Page V8-T5-72.
1
Synchronous design requires source and detector to be wired to one another.
CommonPower
A
B
C
Load
A
off
ON
off
off
B
off
off
ON
off
C
off
off
off
ON
OUTPUT
off
ON
ON
ON
Load
Common
A
B
Power
A
off
ON
off
ON
B
off
off
ON
ON
OUTPUT
off
off
off
ON
Operating
Voltage
Sensing
Range
Optimum
Range Field of View
Thru-Beam
Component Connection Type
Light Operate
Catalog Number
Dark Operate
Catalog Number
Thru-Beam Forward Viewing
20–132 Vac
50/60 Hz or
15–30 Vdc
20 ft (6m) 0.1 to 10 ft
(0.03 to 3m)
20 in (0.5m)
diameter at
10 ft (3m)
Source 6 ft cable 11155AA14 11155AA14
4-pin micro AC connector 11155AA04 11155AA04
Detector 6 ft cable 12155AL10 12155AD10
4-pin micro AC connector 12155AL04 12155AD04
10–30 Vdc 20 ft (6m) 0.1 to 10 ft
(0.03 to 3m)
20 in (0.5m)
diameter at
10 ft (3m)
Source 6 ft cable 11155AA17 11155AA17
4-pin micro DC connector 11155AA07 11155AA07
Detector 6 ft cable 12155AL10 12155AD10
4-pin micro DC connector 12155AL07 12155AD07
Thru-Beam Right Angle Viewing
20–132 Vac
50/60 Hz
or 15–30 Vdc
20 ft (6m) 0.1 to 10 ft
(0.03 to 3m)
20 in (0.5m)
diameter at
10 ft (3m)
Source 6 ft cable 11155RA14 11155RA14
4-pin micro AC connector 11155RA04 11155RA04
Detector 6 ft cable 12155RL10 12155RD10
4-pin micro AC connector 12155RL04 12155RD04
10–30 Vdc 20 ft (6m) 0.1 to 10 ft
(0.03 to 3m)
20 in (0.5m)
diameter at
10 ft (3m)
Source 6 ft cable 11155RA17 11155RA17
4-pin micro DC connector 11155RA07 11155RA07
Detector 6 ft cable 12155RL10 12155RD10
4-pin micro DC connector 12155RL07 12155RD07
Wiring Diagrams, see Page V8-T5-75.
Thru-Beam Forward
Viewing
1
Source
Detector
Thru-Beam Right Angle
Viewing
1
Source
Detector