Cut Sheet

V8-T2-18 Volume 8—Sensing Solutions CA08100010E—August 2015 www.eaton.com
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2.2
Limit Switches
Compact Prewired Switches
Technical Data and Specifications
Compact Prewired Switches
Maximum Ampere Ratings
1
Wiring Diagram
Compact Prewired Switches Micro-Connector Switches
Note
1
Inductive load ratings are tested at a power factor 0.4 min. for AC power and a time constant of 7 ms max. for DC power. Inrush current for
motor load is six times the steady state current.
Description Specification
Contacts 1-SPDT (Form C)
Mechanical life 10,000,000 operations
Electrical life 200,000 operations, 30 operation/min. at rated load
Operating speed 30 operations per minute maximum
Operating temperature range –10° to 70°C (14° to 158°F)
Storage temperature range –10° to 70°C (14° to 158°F)
Humidity 95% maximum non-condensing
Vibration Malfunction durability, 10 to 55 Hz 1.5 mm double amplitude
Shock Malfunction durability, approximately 50G
Enclosure ratings NEMA 4, 6 and 13; IEC IP67
Rated
Voltage
Non-Inductive Load (A) Inductive Load (A)
Resistive Load Inductive Load Motor Load Inrush Current (A)
NC NO NC NO NC NO NC NO
125 Vac55332.51.320 max.10 max.
250 Vac55221.50.8
8 Vdc55541.51.5
14 Vdc55441.51.5
30 Vdc44331.51.5
125 Vdc 0.4 0.4 0.4 0.4 0.05 0.05
250 Vdc 0.2 0.2 0.2 0.2 0.03 0.03
Common
(Black)
NC (Red)
NO (Blue)
Ground
(Green)
3 4
12
Face View of Male Connector
COM 1
2 NC
4 NO
Contacts Rated
1.0A at 124 Vac
1.0A at 30 Vdc
3