Datasheet

Color-coded outlet sections
Color-coded outlet sections match a corresponding
circuit breaker to easily identify which one feeds
corresponding outlets and prevent unbalanced loading
that would unnecessarily trip a breaker.
Outlet grip functionality on standard IEC cable
Eatons patent-pending IEC outlet grip secures plugs in place
with a lever-actuated grip that’s integrated into each outlet.
Once the levers click into the grip position, the plugs are
secured from accidental disconnect due to bumps or vibra-
tions without the need for special power cords.
O is unlocked, + is grip engaged
Outlet switching
Remotely control devices by powering on or off individual
outlets. Save time and operating costs by rebooting
machines from your control center without costly site
visits.
Sequential start up
Make sure your servers start sequentialy to avoid in rush
current and start your database before the application.
Green LED signifies power on and red is power off to outlet
Device reboot and measurement across A and B feed
When connecting multiple source input servers to an A and B
feed power source, the daisy-chain capability allows you to group
power supplies across the ePDU. As a result, all the power
supplies are controlled with a single action, which saves time
rebooting servers with two to six power supplies. The power
consumption is available for each device.
Typical server with multiple power inputs powered by two ePDUs
One percent billing grade accuracy
ePDU G3 provides one
percent revenue-grade
power monitoring for higher
accuracy in department billing
or colocation data centers.
Effectively measure power
usage to all outlets or indi-
vidual outlets.
1
+
-
%
Daisy chain eight units from one IP address
Eatons new patented daisy-chain capability allows
up to eight ePDUs to share the same network
connection and IP address. Unlike competitive rack
PDUs that require a dedicated IP address for best
performance, Eaton technology provides a 87%
percent reduction in network infrastructure costs.
A and B power PDU sharing a network connec-
tion via daisy chain
1
x 8
Features and benefits
Basic
All technologies
Low-prole form factor: Provide zero interference into
the rail space
High 60°C operating temperature: Fully functional
in high operating temperature environments,
resulting in reduced cooling costs
Integrated IEC outlet grips: Integrated lever-actuated grip
that easily secures plugs to prevent accidental disconnect
Color-coded outlet sections: Color-coded outlet
sections match corresponding color-coded
circuit breakers to simplify load balancing
Flexible mounting options: Button mounting on
rear & side + variable mounting system
Standard
All technologies except Basic
One percent billing grade accuracy: Revenue-grade power
monitoring for higher accuracy to help optimize power utilization
Remote site management: Save time from onsite visits
Hot-swap meter: Remove meter without power disruption
to increase uptime while enhancing serviceability
Phase and section metering: Meter color-coded
sections to control power utilization
Advanced LCD pixel display: Allow for
easy IP setup and troubleshooting
Daisy chain (share network connection/IP address): Share
the same network connection and IP address for up to eight
rack PDUs, which will reduce network infrastructure costs
Cybersecurity: The rmware is updated on regulary basis
to keep the ePDU cybersecurity to highest standard.
Advanced
Managed and
Metered Outlet
Measure power consumption at outlet level: Acquire precise
data and gain detailed energy analysis to make informed
decisions and assist with effectivelydeploying equipment
Measure Level 3 PUE: Measuring power at the outlet
level allows users to measure Level 3 Power Usage
Effectiveness (PUE), which provides the possibility of
transforming billing into revenue or utility discounts
Managed and
Switched
Outlet switching: Remotely control devices by
powering on, off or rebooting individual outlets
and set sequential start up across A&B feed
Group reboot for A and B feed: Group multiple power supplies
across the rack PDU to control all with a single action, saving
time when rebooting servers with two or more power supplies
Turn off unused outlets: Control unauthorized use
Advanced LCD pixel display with hot-swap
capability
Eatons new hot-swap eNMC (ePDU Network Management
and Control) module can be replaced without the need to
power down your rack. Increase uptime while enhancing
serviceability and saving on unnecessary service calls.
The menu-driven pixel display allows for easy setup and
troubleshooting.
Module being removed without removing power to the ePDU
Universal Mounting
Models include both rear and side button mounting system
and Eaton's patented variable mounting system.