Cut Sheet

Volume 10—Enclosed Control CA08100012E—June 2015 www.eaton.com V10-T4-3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4.1
Lighting Contactors
UL Rated AC Contactors
Catalog Number Selection
Enclosed Lighting Contactors
Enclosures
Lighting contactors are
available open or mounted in
Type 1, 3R, 4, 4X, 12 or 7/9
enclosures.
Type 1 is for indoor, general
purpose for personal
protection. Knock-outs are
provided in the top and
bottom for conduit entry.
Type 3R is for outdoor
applications and rated for rain,
sleet and external ice buildup.
Type 3R enclosures have
knockouts in the bottom and
provisions for a hub in the
top.
Type 4 and 4X are for
mounting indoor or outdoor
and provide protection from
splashing water, hose-
directed water and wind-
blown dust. Watertight
conduit hubs are provided
in the top and bottom of
Type 4X enclosures. The
standard Type 4X enclosures
are made of 304-Grade
stainless steel, providing
corrosion protection.
316-Grade stainless steel
construction is available as
an upgrade option.
Type 12 enclosures are for
indoor mounting and protect
from dripping liquids, falling
dirt and dust. No knockouts
or hubs are provided with
Type 12 enclosures.
Type 1, 3R, 4 and 12
enclosures are painted with a
polyester urethane powder
coat paint meeting UL
requirements and the color is
ANSI 61 gray. Type 1
enclosures have knockouts
for cover controls. All the
other types have holes
plugged, ready for cover
controls. Type 7/9 is also
available for explosion proof
applications. Please contact
the factory for additional
details.
Notes
1
C30CN available in 30 A only.
2
For normally closed poles see Tab 15.
Design
L = CN35 or A202 lighting contactor
C = C30CN lighting contactor
Class Page
03 = Non-combination electrically held lighting contactor V10-T4-6,
V10-T4-7
04 = Non-combination mechanically held/magnetically
latched lighting contactor
V10-T4-6,
V10-T4-9
12 = Combination electrically held lighting contactor—
fusible disconnect
V10-T4-11
13 = Combination magnetically latched lighting contactor—
fusible disconnect
V10-T4-11
14 = Combination electrically held lighting contactor—
thermal magnetic circuit breaker
V10-T4-12
15 = Combination magnetically latched lighting contactor—
thermal magnetic circuit breaker
V10-T4-12
Ampere Size
1
A = 10 A
B = 20 A
C = 30 A
D = 60 A
E = 100 A
F = 200 A
G = 300 A
H = 400 A
J = 600 A
Modification Codes
(See Pages V10-T4-4 and V10-T4-5 and Tab 15)
Enclosure Types
1 = Type 1—General purpose
2 = Type 3R—Rainproof
3 = Type 4—Watertight (painted)
4 = Type 4X—Watertight (304-Grade stainless steel)
6 = Type 7/9—Explosion proof
8 = Type 12—Dust-tight
9 = Type 4X—Watertight (316-Grade stainless steel)
Disconnect Fuse Clip Ratings
A = None
B = 30 A / 250 V R
C = 30 A / 600 V R
D = 60 A / 250 V R
E = 30 A / 600 V R
F = 100 A / 250 V R
G = 100 A / 600 V R
H = 200 A / 250 V R
J = 200 A / 600 V R
K = 400 A / 250 V R
L = 400 A / 600 V R
M = 600 A / 250 V R
N = 600 A / 600 V R
P = 800 A / 600 V R
T = By description
Thermal-Magnetic Breaker Ratings
A = None
D = 20 A
E = 30 A
F = 60 A
G = 100 A
H = 200 A
J = 300 A
K = 400 A
L = 600 A
M = 800 A
T = By description
Number of Poles
2
1, 2, 3, 4, 5, 6, 7, 8, 9 = Poles required
A = 10 poles
B = 12 poles
C = 20 poles
Combination Devices = Three-pole only
Coil Voltage
A = 120/60 110/50
B = 240/60 220/50
C = 480/60 440/50
D = 600/60 550/50
E = 208/60
G = 550/50
H = 277/60
J = 208–240/60
K = 240/50
L = 380/50
M = 415/50
P = 12 Vdc
Q = 24 Vdc
R = 48 Vdc
S = 125 Vdc
T = 24/60
U = 24/50
V = 32/50
W = 48/60
X = 104–120/60
Y = 48/50
Z = By description
EC L 12 D 1 A 3 E -X