6.1
Pump Panels
Industrial Pump Panels
●
Enclosure—Type 3R
rainproof and sleet
resistant construction with
stainless steel door latches
and special corrosion
resistant paint. Enclosure
features include grounding
lugs, padlocking feature on
door latch, drip hood over
door and provisions for top
mounting conduit hubs.
Most enclosures include
generous panel space for
mounting optional control
and accessories
●
Mounting—Pole mounting
feet with keyhole slots for
easy mounting are
standard on enclosures for
Sizes 1–5 (removable for
Sizes 1–5 standard width
flange type enclosures).
Brackets can be formed to
the contour of the pole
after mounting
●
Padlocking—Provision on
door latch for locking door
closed, as well as provision
for padlocking disconnect
switch in OFF position.
With a simple modification,
disconnect can also be
padlocked in ON position
●
UL Listed—Underwriters
Laboratories Inc. includes
the “Suitable for Use as
Service Equipment” label
Interrupting Ratings
●
Fusible—Sizes 1–5
suitable for use on a circuit
capable of delivering not
more than 100,000 rms
symmetrical amperes.
600V maximum where a
Class R fuse clip kit is
properly installed and Class
R fuses are used. If Class
R fuses are not used, the
switch should not be
installed on circuits capable
of delivering more than
10,000 rms symmetrical
amperes. Size 6 is limited
to 18,000 and Size 7 is
limited to 30,000 rms
symmetrical amperes
●
Circuit Breaker—Sizes
1–3 controllers are suitable
for use on circuits capable
of delivering not more than
100,000 rms symmetrical
amperes at 480V maximum;
for 600V applications not
more than 65,000 rms
symmetrical amperes
●
ECP Irrigation Pump
Panel—Suitable for use on
circuits capable of
delivering not more than
10,000 rms symmetrical
amperes at 480V
maximum
Standards and Certifications
Note: See Ta b 17 for additional
information on standards and
certifications that apply to all
enclosed control products.
●
UL Listed
●
cUL Listed (indicates
appropriate CSA Standard
investigation)
●
ABS Type Approved
●
OSHPD Certified
(OSP-0015-10)
Additional Reference
Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V10-T6-5
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ta b 1 4
Accessories and Modifications . . . . . . . . . . . . . . Ta b 1 5
Technical Data and Specifications . . . . . . . . . . . . Ta b 1 7
Optional Features
●
Backspin Timer—
0.2 seconds to 3 minutes.
Prevents restart until motor
and pump have stopped
●
Program Timer—24 hour,
7 day with day omission
●
Control Transformer—
Available as standard,
either as a field kit or
factory installed. Includes
two primary and one
secondary fuses
●
Electrical Interlocks—Side
mounted in NO, NC and
NO-NC. Maximum of
two contacts on either side
of starter through Size 2,
maximum of three per side
Sizes 3–5
●
Control Circuit Fuse Kit—
30A, 600V rating
●
Lightning Arrestor—
Offers protection to control
from lightning induced
surges
●
“R” Fuse Clip Kits—
30–200A, 250V and 600V
ratings
●
Disconnect Control
Circuit Interlock—To
disconnect separate
control circuits
●
Enclosure Conduit
Hubs—Hole provided in
enclosure top covered with
hole closer. Will accept
3/4 in, 1-1/4 in, 1-1/2 in,
2 in, 2-1/2 in, and three
inconduit sizes
●
Pad Mounting Feet—For
standard width enclosures
Sizes 1–5
●
Electronic Overload
(SSOL)
●
304-Grade Stainless
Steel Enclosure—For
additional corrosion
resistance, any of the
pump panels can be
ordered as 304-Grade
stainless steel, still keeping
the Type 3R rating
●
Soft Starter Pump
Control Options
●
Designed to reduce
“water-hammer” during
start-up and stopping
sequences
●
Stop ramp extended to
60 seconds to help
control larger motors
and systems with long
piping runs