Cut Sheet

Volume 10—Enclosed Control CA08100012E—June 2015 www.eaton.com V10-T3-43
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3.1
IEC Contactors and Starters
XT IEC Power Control
Enclosed XT Combination Motor Controller
Contents
Description Page
Non-Metallic Enclosure—Contactors and Starters . . .
V10-T3-2
Metallic Enclosure—Contactors and Starters
. . . .
V10-T3-8
Combination Motor Controllers
Catalog Number Selection . . . . . . . . . . . . . . . . V10-T3-44
Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . V10-T3-45
Product Selection
Non-Reversing Starters . . . . . . . . . . . . . . . . V10-T3-46
Non-Reversing Starters with CPT . . . . . . . . V10-T3-46
Reversing Starters . . . . . . . . . . . . . . . . . . . . V10-T3-47
Combination Motor Controllers
Product Description
Eaton’s XT line includes
IEC contactors, starters
and combination motor
controllers (CMCs). Designed
to meet international
standards, the enclosed
control XT line (ECX), carries
UL and cUL certifications.
Features and Benefits
ON/OFF rotary handle with
lockout provision
Visible trip indication
Test trip function
Motor applications from
0.11 A to 32 A
Class 10 overload
protection
Built-in heater and
magnetic trip elements
to protect the motor
Phase loss sensitivity
Type 2 coordination
Ambient compensated
up to 55 °C [140 °F]
Control inputs located at
front of starter for easy
access and wiring
Wide range of coils
DIN rail mount—XTSC…BB_
Additional Reference
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ta b 1 4
Accessories and Modifications . . . . . . . . . . . . . . Ta b 1 5
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . Ta b 1 6
Technical Data and Specifications . . . . . . . . . . . . Ta b 1 7
Mounting plates—
XTSC…BC_, XTSC…D
motor controllers
Adjustment dial for setting
motor FLA
Short-circuit trip at
14 times the maximum
setting of the FLA
adjustment dial
UL 508 Type F CMC high
fault short-circuit ratings;
refer to manual motor
protectors in
CA08102001E
Non-metallic and metallic
enclosures in Types 1
(IP23), 4 (IP66), 4X (IP66)
and 12 (IP65)
Opaque (standard) or
clear covers available on
non-metallic Halyester
enclosure
Standards and Certifications
Note: See Ta b 17 for additional
information on standards and
certifications that apply to all
enclosed control products.
UL Listed
cUL Listed (indicates
appropriate CSA Standard
investigation)
Short-Circuit Ratings
0–12 A / B-frame MMP
with B-frame contactor
50K AIC at 600 V
13–32A/B-frame MMP
with C-frame contactor
18K AIC at 600 V