3.1
IEC Contactors and Starters
XT IEC Power Control
IEC Metallic Enclosure—Contactors and Starters
Contents
Description Page
Non-Metallic Enclosure—Contactors and Starters . .
V10-T3-2
Metallic Enclosure—Contactors and Starters
Catalog Number Selection . . . . . . . . . . . . . . . . V10-T3-9
Product Selection
Non-Combination Starters . . . . . . . . . . . . . V10-T3-14
Combination Starters . . . . . . . . . . . . . . . . . V10-T3-23
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . V10-T3-35
Combination Motor Controllers . . . . . . . . . . . . . . . V10-T3-43
Metallic Enclosure—Contactors and Starters
Product Description
Eaton’s XT line includes
IEC contactors, starters
and combination motor
controllers (CMCs). Designed
to meet international
standards, the enclosed
control XT line (ECX), carries
UL and cUL certifications.
Features and Benefits
AC control from 12 V to
600 V 50/60 Hz
DC control from 24 V to
220 V
Available with screw or
spring cage terminals
Reversing or non-reversing
contactors and starters
AC-3 contactor ratings to
1000 A and AC-1 contactor
ratings to 2000 A
Non-reversing starters to
650 A
Panel or DIN rail mounting
to 65 A
IP20 finger and back-of-
hand proof
Large ambient temperature
range, –25 °C to +50 °C
[–13 °F to +122 °F]
Additional Reference
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ta b 1 4
Accessories and Modifications . . . . . . . . . . . . . . . Ta b 1 5
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ta b 1 6
Technical Data and Specifications . . . . . . . . . . . . . Ta b 17
AC and DC controlled
contactors in the same
compact frame
Low power consumption
DC coils
Built-in NO or NC auxiliary
contacts to 32 A
Plug-in accessories for
reduced installation time
Types 1 (IP23), 4 (IP66), 4X
(IP66), 12 (IP65) and 3R
(IP32)
Circuit breakers, fused,
non-fused and non-
combination designs
available
Opaque (standard) or clear
covers available on non-
metallic Halyester
enclosure option
Standards and Certifications
Note: See Ta b 17 for additional
information on standards and
certifications that apply to all
enclosed control products.
Fusible—with Class J
fuses
UL Listed
cUL Listed
1
Circuit Breaker HMCP/E
UL Listed
cUL Listed
1
Short-Circuit Ratings
Fused, non-fused
10K AIC at 600 V
HMCP
0–10 hp 15K AIC
at 600 V
15–125 hp 25K AIC
at 600 V
Non-combination
0–1 hp 1K AIC at 600 V
1.5–50 hp 5K AIC
at 600 V
50–200 hp 10K AIC
at 600 V
Note
1
cUL Listing indicates appropriate CSA
standard investigation.