Cut Sheet

Volume 10—Enclosed Control CA08100012E—June 2015 www.eaton.com V10-T4-13
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4.1
Lighting Contactors
UL Rated AC Contactors
Accessories
Auxiliary Contacts
C30CN Electrically Held
Contactors—The base
C30CN product line can
accept up to four auxiliary
contacts (2NO/2NC), which
are mounted on the top of the
unit. The auxiliary contacts,
rated A600, are also suitable
for use on low-level circuits
down to 12 V, 5 mA.
CN35 Electrically Held
Contactors—Include a NO
maintaining auxiliary contact
mounted on the right side of
the contactor or integral to
the contactor. The 10–60 A
devices will accept additional
auxiliary contacts on the top
(front) and/or sides. The 100–
400 A sizes will accept side-
mounted auxiliaries only.
Mechanically Held and
Magnetically Latched
Holding circuit auxiliary
contact, if needed, is not
included and should be added
separately as an option.
Power Poles for C30CN
The C30CN can be configured
with up to 12 poles (30 A
maximum per pole). Power
poles are available in single or
double pole designs and can
be mounted to provide either
normally open or normally
closed operation with a
maximum of 12 NO poles or
8 NC and 4 NO poles. Each
pole is capable of accepting
up to 8 AWG wire.
Two-Wire or Three-Wire
Control Module for C30CN
A mechanical latch with a
two- or three-wire electronic
control module delivers
reliable performance and
protection from such
application abnormalities as
line noise, leakage currents
from controller outputs, or
short repetitive commands
burst from faulty controllers.
For enclosed control, units
come standard with two-wire
control.
IMPORTANT: Add the C18
modification code to get
three-wire control with the
C30CN contactor.
Mechanically Held Kit for
C30CN
A modification kit allows the
conversion of an electrically
held lighting contactor into a
mechanically held contactor.
Coil Kits for C30CN
The C30CN line comes in a
wide range of input voltages
and with coils from 24 Vac to
600 Vac.
Two-Wire Control Relay
for A202
The two-wire control relay is
designed to field convert
three-wire magnetically
latched lighting contactors to
operate controls such as
photocells and timers.
Terminal blocks included for
fast wiring installation.
Type 1 Two-Wire Control Relay
Description
Magnetic
Coil Voltage
Type 1 Type 3R
Catalog Number Catalog Number
Two-wire
control relay
120 ECLC201A ECLC202A
208 ECLC201E ECLC202E
240 ECLC201B ECLC202B
277 ECLC201H ECLC202H
480 ECLC201C ECLC202C
Enclosed Lighting
Contactors