Volume 10—Enclosed Control CA08100012E—November 2012 www.eaton.com V10-T5-35
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5.3
Reduced Voltage Starter
Freedom Three-Phase Magnetic Starters
Catalog Number Selection
Freedom Three-Phase Magnetic Starters
Magnetic Coil Codes (System Voltage)
2
Notes
1
Use for Sizes 0–3, HMCP 600V applications only.
2
When control power transformer modification codes (C1C11) are used or when starter class
includes CPT (that is, ECN07, 18) see table to the right for system voltage code.
Control Power Transformer Codes (System Voltage)
Design
N = Freedom NEMA
Cover Control
See Page V10-T5-36 for options
Coil Voltage and/or Control Transformers
See code tables below
Class Page
42 = Non-combination autotransformer starter V10-T5-37
43 = Combination autotransformer starter—fusible disconnect V10-T5-39
Combination autotransformer starter—non-fusible
disconnect
V10-T5-41
44 = Combination autotransformer starter—circuit breaker V10-T5-43
45 = Non-combination part winding starter V10-T5-45
46 = Combination part winding starter—fusible disconnect V10-T5-46
Combination part winding starter—non-fusible disconnect V10-T5-48
47 = Combination part winding starter—circuit breaker V10-T5-49
48 = Non-combination open transition wye delta starter V10-T5-51
49 = Combination open transition wye delta starter—
fusible disconnect
V10-T5-52
Combination open transition wye delta starter
non-fusible disconnect
V10-T5-56
50 = Combination open transition wye delta starter—
circuit breaker
V10-T5-60
51 = Non-combination closed transition wye delta starter V10-T5-64
52 = Combination closed transition wye delta starter—
fusible disconnect
V10-T5-68
Combination closed transition wye delta starter—
non-fusible disconnect
V10-T5-72
53 = Combination closed transition wye delta starter—
circuit breaker
V10-T5-76
64 = Combination part winding pump control starter—fusible V10-T5-80
65 = Combination part winding pump control starter—
circuit breaker
V10-T5-80
Enclosure Type
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
Type 1—General purpose
Type 3R—Rainproof
Type 4—Watertight (painted steel)
Type 4X—Watertight (304-Grade stainless steel)
Type 4X—Corrosion (non-metallic)
Type 7/9—Bolted hazardous location
Type 7/9—Threaded hazardous location
Type 12—Dust-tight
Type 4X—316-Grade stainless steel
NEMA Size
2 =
3 =
4 =
5 =
Size 2
Size 3
Size 4
Size 5
6 =
7 =
8 =
9 =
Size 6
Size 7
Size 8
Size 9
Modification Codes
See Tab 15
Disconnect Fuse Clip Ratings
A =
B =
C =
D =
E =
F =
None
30A/250V R
30A/600V R
60A/250V R
60A/600V R
100A/250V R
G =
H =
J =
K =
L =
M =
100A/600V R
200A/250V R
200A/600V R
400A/250V R
400A/600V R
600A/250V R
N =
P =
Q =
R =
S =
T =
600A/600V R
800A/600V L
1200A/600V L
1600A/600V L
2000A/600V L
By description
Circuit Breaker Ratings
A =
B =
C =
D =
E =
F =
G =
H =
J =
None
3A
7A
15A
30A
50A
100A
150A
250A
K =
L =
M =
N =
P =
Q =
R =
T =
400A
600A
800A
1000A
1200A
2000A
3000A
By description
5 =
6 =
7 =
8 =
9 =
I =
2 =
3A
1
7A
1
15A
1
30A
1
50A
1
100A
1
70A
EC N 42 2 1 A A F - 0000
Code Magnet Coil Code Magnet Coil Code Magnet Coil
A 120/60110/50 K 240/50 U 24/50
B 240/60220/50 L 380/50 V 32/50
C 460/60440/50 M 415/50 W 48/60
D 575/60550/50 P 12 Vdc X 104–120/60
E 208/60 Q 24 Vdc Y 48/50
G 550/50 R 48 Vdc Z By description
H 277/60 S 125 Vdc
J 208–240/60 T 24/60
Code Primary Secondary
B 240/480–220/440 wired for 240V 120/60–110/50
C 240/480–220/440 wired for 480V 120/60–110/50
D 600/60–550/50 120/60–110/50
E 208/60 120/60
H 277/60 120/60
L 380/50 110/50
M 415/50 110/50
Q 208/60 24
R 240/480–220/440 wired for 240V 24
S 240/480–220/440 wired for 480V 24
T 600/60 24
U 277/60 24
V 380/50 24
W 415/50 24
X 240/480/600 wired for 480V 120
Y 240/480/600 wired for 480V 24
Z By description