15.1
Accessories and Modification Codes
Accessories
Type J Auxiliary Contact for A202/ECL
Capable of being field
mounted in a contactor or
starter (Classes A200,
A900 Sizes 00–6, V200,
V201 vacuum and definite
purpose controllers)
Provides two separate
electrical contact sets
which wire vertically and
are color coded; black
designates NC and silver
designates NO. Please
note that the vertical wiring
is contrary to the horizontal
wiring of the L-56 auxiliary
contacts
Designed to fit within
dimensions of starter; no
additional panel space is
required
Provides circuit isolation
(no polarity restrictions)
and single break bifurcated
contacts
Auxiliary Contact Ratings
Auxiliary Contact Types
SS-56 Surge Suppressor for A202/ECL
Designed to be used with
magnetic motor controllers
through Size 4 in 120V,
60 Hz control circuit
applications where
electronic equipment is
used
Steady state coil volts: 120,
60 Hz, rms
Peak input volts: 169.6,
60 Hz, max. amplitude
Max. ambient temperature:
65°C
Nominal limiting volts:
270 peak
Nominal rate of volt rise:
0.5 per ms
Surge Suppressor
1
Voltage Make Break
NEMA A600
120–600 Vac 7200 VA 720 VA
72–120 Vac 60A 720 VA
28–72 Vac 60 VA 10A
NEMA R300
28–300 Vdc 28 VA 28 VA
Contact Type Max. Catalog Number
1NO and 1NC 4 J11
2NC 4 J02
2NO 4 J20
1 coil clearing
NC and 1NO
4 J1C
Type J Auxiliary
Contact
Type Mounting
Kit
Catalog Number
Starter SS-56
SS-56 Surge Suppressor
F-56 Fuse Block for A202/ECL
Facilitates installation of
fuses (15A, 600V maximum)
in control circuits
Uses Bussman type KTK
fuses, or equivalent
Mounts in same cavity as
Type J auxiliary contact
No tools or mounting
hardware needed
Fuse not included
Fuse Block
R-56 Interposing Relay for A202/ECL
The R-56AA interposing relay
is a low energy solid-state
device with a single NO solid-
state contact. It can be used
as a 120 Vac control relay, and
will operate on as little as
40 Vac input. Is useful in
applications requiring long
control wiring runs where
excessive voltage drop would
prevent the contactor or relay
from energizing. Will operate
a Size 4 contactor from
10,000 ft using 18 AWG wire.
Interposing Relay
Power Pole Kit for A202/ECL
Adds 1NO or 1NC power
pole to Size 00–1 A201
Class contactors
Factory installed or field
mountable in load side
auxiliary cavities
600 Vac
Continuous current rating
of 18A for Size 0, 27A for
Size 1
Power Pole Kit
2
Notes
1
Can be used on Sizes 5 and 6 with 120V coil. Mounting bracket required—order separately.
Mounting bracket 177C043G04.
2
Do not use with DC operated contactors.
Mounting
Kit
Catalog Number
Starter F56
Panel F56-P
Typ e
Mounting
Kit
Catalog Number
Starter or panel R56-AA
Continuous
Current Rating
Kit
Size
Kit
Catalog Number
Normally Open
18 0 PNO-0
27 1 PNO-1
Normally Closed
18 0 PNC-0
27 1 PNC-1