2.1
NEMA Contactors and Starters
Freedom Full Voltage Controls
Catalog Number Selection
NEMA Freedom Line Enclosed Control
Magnetic Coil Codes (System Voltage)
2
Notes
1
Use for 0–3, HMCP 600 V applications only.
2
When control power transformer modification codes (C1C11) are used or when starter class
includes CPT (that is ECN07, 18) see the table at right for system voltage code.
Control Power Transformer Codes (System Voltage)
Enclosure Type
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
Type 1—General purpose
Type 3R—Rainproof
Type 4—Watertight (painted steel)
Type 4X—Watertight (304-Grade stainless steel)
Type 4X—Corrosion (non-metallic)
Type 7/9—Bolted hazardous location
Type 7/9—Threaded hazardous location
Type 12—Dust-tight
Type 4X—316-Grade stainless steel
Design
N = Freedom NEMA
2 = A200
Class Page
01 = Non-reversing contactor—three-pole V10-T2-10
Non-reversing contactor—two-pole V10-T2-12
Non-reversing contactor—four-pole V10-T2-14
Non-reversing contactor—five-pole V10-T2-15
02 = Reversing contactor—three-pole V10-T2-16
05 = Non-combination non-reversing starter V10-T2-18
05 = Non-combination single-phase non-reversing starter V10-T2-20
06 = Non-combination reversing starter V10-T2-21
07 = Non-combination non-reversing starter with CPT V10-T2-23
16 = Combination non-reversing starter—fusible
disconnect
V10-T2-25
Combination non-reversing starter—non-fusible
disconnect
V10-T2-27
Special enclosure combination non-reversing
starter—fusible/non-fusible disconnect
V10-T2-29
17 = Combination reversing starter—fusible disconnect V10-T2-31
Combination reversing starter—non-fusible
disconnect
V10-T2-33
18 = Combination non-reversing starter—fusible
disconnect with CPT
V10-T2-35
Combination non-reversing starter—non-fusible
disconnect with CPT
V10-T2-37
22 = Combination non-reversing starter—circuit breaker V10-T2-39
Special enclosure combination non-reversing
starter—circuit breaker
V10-T2-42
23 = Combination reversing starter—circuit breaker V10-T2-44
24 = Combination non-reversing starter—circuit breaker
with CPT
V10-T2-47
NEMA Size
A =
0 =
1 =
2 =
Size 00
Size 0
Size 1
Size 2
3 =
4 =
5 =
6 =
Size 3
Size 4
Size 5
Size 6
7 =
8 =
9 =
Size 7
Size 8
Size 9
Modification/Overload Codes
All modification codes, see Tab 15.
For solid-state overload codes, Page V10-T2-5
EC N 22 2 1 A A F - 0000
Disconnect Fuse Clip Ratings
A =
B =
C =
D =
E =
F =
None
30 A/250 V R
30 A/600 V R
60 A/250 V R
60 A/600 V R
100 A/250 V R
G =
H =
J =
K =
L =
M =
100 A/600 V R
200 A/250 V R
200 A/600 V R
400 A/250 V R
400 A/600 V R
600 A/250 V R
N =
P =
Q =
R =
S =
T =
600 A/600 V R
800 A/600 V L
1200 A/600 V L
1600 A/600 V L
2000 A/600 V L
By description
Circuit Breaker Ratings
A =
B =
C =
D =
E =
F =
W =
G =
None
3 A
7 A
15 A
30 A
50 A
70 A
100 A
H =
J =
K =
L =
M =
N =
P =
Q =
150 A
250 A
400 A
600 A
800 A
1000 A
1200 A
2000 A
R =
T =
5 =
6 =
7 =
8 =
9 =
I =
3
000 A
By description
3 A
1
7 A
1
15 A
1
30 A
1
50 A
1
100 A
1
Coil Voltage and/or Control Transformers
See code tables below
Cover Control
Type 1 non-comb. (NEW BOX 1 only), Page V10-T2-6
Type 1 non-comb., Page V10-T2-7
All others, Page V10-T2-8
Contactors
3 = Three poles
Code Magnet Coil Code Magnet Coil Code Magnet Coil
A 120/60–110/50 K 240/50 U 24/50
B 240/60–220/50 L 380/50 V 32/50
C 460/60–440/50 M 415/50 W 48/60
D 575/60–550/50 P 12 Vdc X 104–120/60
E 208/60 Q 24 Vdc Y 48/50
G 550/50 R 48 Vdc Z By description
H 277/60 S 125 Vdc
J 208–240/60 T 24/60
Code Primary Secondary
B 240/480–220/440 wired for 240 V 120/60–110/50
C 240/480–220/440 wired for 480 V 120/60–110/50
D 600/60–550/50 120/60–110/50
E 208/60 120/60
H 277/60 120/60
L 380/50 110/50
M 415/50 110/50
Q 208/60 24
R 240/480–220/440 wired for 240 V 24
S 240/480–220/440 wired for 480 V 24
T 600/60 24
U 277/60 24
V 380/50 24
W 415/50 24
X 240/480/600 wired for 480 V 120
Y 240/480/600 wired for 480 V 24
Z By description