Cut Sheet

V10-T15-8 Volume 10—Enclosed Control CA08100012E—June 2015 www.eaton.com
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15.1
Accessories and Modification Codes
Accessories
DC Magnet Coils
When Ordering Specify
Conversion Kit for Field
Assembly
Catalog number
Factory Installed DC Coil
For factory installed DC
magnet coil on AC
contactors or non-
combination starters (open
type only), substitute the
code suffix from table
below for the magnet coil
identifier in the device
catalog number.
Example: For Size 0 AC
contactor with a 24 Vdc
coil, change CN15BN3AC
to CN15BN3T1C
Application
Connect for separate
control
Not for use with cover
control switch operators
Use twin break, heavy-duty
pilot devices
Designed for +10%, –20%
rated voltage, continuous
duty operation
Non-Reversing Kit Consists of:
One encapsulated DC
magnet coil
One NCI or NO/NCI side-
mounted auxiliary contact
Note: These kits are supplied
with a NO/NCI side-mounted
auxiliary contact in place of the
NCI contact.
Two blue colored
connection wires
One instruction publication
Operation
These DC coil kits have
separate pickup and seal
windings. A special (side-
mounted) early-break NCI
auxiliary contact is used to
either disconnect the pickup
winding or insert the seal
winding in series with the
pickup winding, depending on
the frame size of the
contactor. DC coil kits come
in two styles, a suffix 1 and a
suffix 4. The 1 suffix contains
only the special (side-
mounted) early break NCI
auxiliary contact. The 4 suffix
contains a NO contact in the
same package as the special
(side-mounted) early-break
NCI auxiliary contact.
Note: NEMA Sizes 00 and 0
contactors may use either suffix 1
or 4 DC coil kits; starters
may use suffix 4 DC coil kits only.
For NEMA Sizes 1 and 2, both
contactors and starters may use a
suffix 4 DC coil kit only.
On the above sizes only,
when the special auxiliary
package is mounted on the
side of a contactor or starter,
no standard auxiliary contact
may be mounted on the
same side.
Note: For NEMA Sizes 3–5, the
special coil NCI clearing contact is
an add-on auxiliary (must mount
on a base mount auxiliary
contact; normally a 1NO). This
arrangement will normally account
for two of the three contact
positions on the side of each
contactor or starter.
See figure on Page
V10-T15-9.
Product Selection
Note
1
These kits are supplied with a NO/NCI side-mounted auxiliary contact in place of the NCI contact.
Contactor or
Starter Size
Conversion Data
Factory Installed Complete Conversion Kit
Volts
Magnet Coil
NCI
Interlock
NumberNEMA
Coil
Number
Amps
P.U./Seal
Watts
P.U./Seal
Code
Suffix
Ship Wt.
Lbs (kg) Catalog Number
Non-Reversing—Kit includes NCI Side-Mounted Auxiliary Contact
00 and 0
CN35–A, B, D
D15 relays
12 9-2988-11 6.4/0.28 76.8/3.36 C320KGD1 R1 1.0 (0.5) C335KD3R1
24 9-2988-12 3.2/0.14 76.8/3.36 C320KGD1 T1 C335KD3T1
48 9-2988-13 1.6/0.07 76.8/3.36 C320KGD1 W1 C335KD3W1
120 9-2988-14 0.64/0.028 76.8/3.36 C320KGD1 A1 C335KD3A1
1
00 and 0
CN35–A, B, D
D15 relays
12 9-2988-11 6.4/0.28 76.8/3.36 C320KGD2
1
R4 1.0 (0.5) C335KD3R4
24 9-2988-12 3.2/0.14 76.8/3.36 C320KGD2
1
T4 C335KD3T4
48 9-2988-13 1.6/0.07 76.8/3.36 C320KGD2
1
W4 C335KD3W4
120 9-2988-14 0.64/0.028 76.8/3.36 C320KGD2
1
A4 C335KD3A4
1 and 2
CN35–G
12 9-2990-1 15.4/0.42 185/4.98 C320KGD5 R4 1.0 (0.5) C335KD4R4
24 9-2990-2 7.7/0.21 185/4.96 C320KGD5 T4 C335KD4T4
48 9-2990-3 3.9/0.11 185/5.04 C320KGD5 W4 C335KD4W4
120 9-2990-4 1.5/0.041 185/4.87 C320KGD5 A4 C335KD4A4
3
CN35–K
12 9-3002-1 24/0.40 293/4.84 C320KGD3 R1 2.0 (0.9) C335KD5R1
24 9-3002-2 12/0.20 288/4.75 C320KGD3 T1 C335KD5T1
48 9-3002-3 6.1/0.097 295/4.67 C320KGD3 W1 C335KD5W1
120 9-3002-4 2.5/0.038 298/4.57 C320KGD3 A1 C335KD5A1
4 and 5
CN35–N, S
24 9-2026-4 18/0.22 400/5.3 C320KGD3 T1B 2.5 (1.1) C335KA3T1
48 9-2026-3 9/0.11 400/5.2 C320KGD3 W1B C335KA3W1
120 9-2026-2 3.3/0.05 450/5.4 C320KGD3 A1B C335KA3A1
240 9-2026-1 1.7/0.02 440/4.9 C320KGD3 B1B C335KA3B1