Cut Sheet

Volume 10—Enclosed Control CA08100012E—June 2015 www.eaton.com V10-T15-41
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15.2
Accessories and Modification Codes
Modification Codes
C—Control Power Transformer, Power Supplies, Control Relays, Cover Control (not elsewhere
defined), Current Transformers, Compelling Relay, Control Wiring, Control Circuit Breaker,
Separate Control, Customer-Supplied Components, Contactors, Counter, E-Stop Relay, DC/AC
Interface, Separate Source Disconnect, Bypass Contactors
Note
1
Not available for XT starters.
Modification Description
Catalog Number
Suffix
Control power transformers
Make sure eighth character specifies
primary/secondary voltage
Standard size control transformer, 120V/60 Hz, 110V/50 Hz secondary with
two primary and one secondary fuse
C1
Standard size control transformer, 24V/60 Hz secondary with two primary
and one secondary fuse
C2
50 VA extra capacity CPT 120V/60 Hz, 110V/50 Hz with two primary and
one secondary
C42
100 VA extra capacity CPT, 120V/60 Hz, 110V/50 Hz secondary with two primary
and one secondary fuse
C3
100 VA extra capacity CPT, 24V/60 Hz secondary with two primary and one
secondary fuse
C4
200 VA extra capacity CPT, 120V/60 Hz, 110V/50 Hz secondary with two primary
and one secondary fuse
C5
200 VA extra capacity CPT, 24V/60 Hz secondary with two primary and one
secondary fuse
C6
300 VA extra capacity CPT, 120V/60 Hz, 110V/50 Hz secondary with two primary
and one secondary fuse
C7
400 VA extra capacity CPT, 120V/60 Hz, 110V/50 Hz secondary with two primary
and one secondary fuse
C8
1 kVA extra capacity CPT, 120V/60 Hz, 110V/50 Hz secondary with two primary
and one secondary fuse
C9
2 kVA extra capacity CPT, 120V/60 Hz, 110V/50 Hz secondary with two primary
and one secondary fuse
C10
Control transformer—order by description C11
CPT with power supply for XT C34
Power supplies (XT only) Separate control 120 Vac to 24 Vdc C27
Power supply with extra capacity—order by description C28
Control relays Four-pole interposing relay, 600V (2NO/2NC) C12
Four-pole, unwired, A600 rtg.—2NO-2NC C14
Eight-pole, unwired, A600 rtg.—4NO-4NC C15
Control relay—order by description C16
Three-wire control module (C30 lighting) C18
1
Two-wire control relay for mechanical/magnetic lighting contactors C20
1
Cover control Convert position seven to E30 type cover control C17
Lock-off attachment added on cover control C19
Change to M22 (22 mm) cover controls C29
Current transformer(s) In phase 1 C21
In phases 1 and 2 C22
In 3 phases C23
Compelling relay C25
Control wiring Omit control wiring C26
With separate control wiring and two 250V fuses in holder C30
With common control wiring and two 600V (Class C) fuses in holder C31
Control wiring type—order by description C33
Control circuit breaker Order by description C32
Separate control Wired for separate control (reduced voltage) C35
Customer supplied components Customer supplied components to be installed C36
Customer supplied wiring diagram to use C37