Installation Manual

Installation Requirements
H-Max Series Adjustable Frequency Drive MN04008005E—September 2011 www.eaton.com 35
Disconnect the RFI-filters from ground by removing the
EMC-jumpers using long-nose pliers or similar. See figure
below.
Removing the Jumper, FS5 as Example
Frames FS7 and FS8
Follow the procedure described below to modify the EMC
protection of the AC drive of frames FS7 and FS8 to
EMC-level C4.
Remove the main cover of the AC drive and locate the jumper.
FS8 only: Push down the grounding arm. See figure below.
Grounding Bar Location, FS8