Cut Sheet

V7-T9-58 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—July 2015 www.eaton.com
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9.1
Connectivity Solutions
SmartWire-DT In-Panel and On-Machine Wiring Solution
Pilot Device Modules
Description Unit M22-SWD-K11 M22-SWD-KC11 M22-SWD-LED-_ M22-SWD-LEDC-_ M22-SWD-K11-LED_
General
Standards IEC/EN 61131-2
EN 50178
IEC/EN 61131-2
EN 50178
IEC/EN 61131-2
EN 50178
IEC/EN 61131-2
EN 50178
IEC/EN 61131-2
EN 50178
Dimensions (W x H x D) in
(mm)
0.47 x 1.65 x 1.54
(12 x 42 x 39)
0.47 x 1.77x 1.46
(12 x 45 x 37)
0.39 x 1.65 x 1.77
(10 x 42 x 45)
0.39 x 1.77 x 1.65
(10 x 45 x 42)
0.47 x 1.65 x 1.77
(12 x 42 x 45)
Weight lbs (g) 0.022 (10) 0.022 (10) 0.022 (10) 0.022 (10) 0.022 (10)
Mounting position As required As required As required As required As required
Ambient Conditions, Mechanical
Degree of protection (IEC/EN 60529) IP20 IP20 IP20 IP20 IP20
Vibrations (IEC/EN 61131-2:2008)
Constant amplitude 3.5 mm Hz 5–8.4 5–8.4 5–8.4 5–8.4 5–8.4
Constant acceleration 1 g Hz 8.4–150 8.4–150 8.4–150 8.4–150 8.4–150
Mechanical shock resistance
(IEC/EN 60068-2-27) semi-sinusoidal
15 g/11 ms
Impacts99999
Drop to IEC/EN 60068-2-31 (drop height) in (mm) 1.97 (50) 1.97 (50) 1.97 (50) 1.97 (50) 1.97 (50)
Free fall, packaged (IEC/EN 60068-2-32) ft (m) 1.0 (0.3) 1.0 (0.3) 1.0 (0.3) 1.0 (0.3) 1.0 (0.3)
Electromagnetic Compatibility (EMC)
Overvoltage category Not applicable Not applicable Not applicable Not applicable Not applicable
Pollution degree 22222
Electrostatic discharge (IEC/EN 61131-2:2008)
Air discharge (Level 3)kV88888
Contact discharge (Level 2)kV44444
Electromagnetic fields (IEC/EN 61131-2:2008)
80–1000 MHz V/m 10 10 10 10 10
1.42 GHz V/m33333
22.7 GHz V/m11111
Radio interference suppression (SmartWire-DT) EN 55011 Class A EN 55011 Class A EN 55011 Class A EN 55011 Class A EN 55011 Class A
Burst (IEC/EN 61131-2:2008, Level 3)
Supply cables kV22222
SmartWire-DT cables kV11111
Radiated RFI (IEC/EN 61131-2:2008, Level 3) V 10 10 10 10 10
Climatic Environmental Conditions
Operating ambient temperature (IEC 60068-2) °F (°C)
–22° to 131° (–30° to 55°) –22° to 131° (–30° to 55°) –22° to 131° (–30° to 55°) –22° to 131° (–30° to 55°) –22° to 131° (–30° to 55°)
Condensation Prevent with suitable measures
Storage °F (°C)
–40° to 176° (–40° to 80°) –40° to 176° (–40° to 80°) –40° to 176° (–40° to 80°) –40° to 176° (–40° to 80°) –40° to 176° (–40° to 80°)
Relative humidity, noncondensing
(IEC/EN 60068-2-30)
% 9–95 9–95 9–95 9–95 9–95
SmartWire-DT Network
Station type SmartWire-DT station (node)
Address allocation Automatic Automatic Automatic Automatic Automatic
SmartWire-DT status LED Green Green Green Green Green
Connections
Plug 8-pole 8-pole 8-pole 8-pole 8-pole
Plug connectors SWD4-8SF2-5 M22-SWD-I_LP SWD4-8SF2-5 M22-SWD-I_LP SWD4-8SF2-5
Number of insertion cycles
>
50
>
50
>
50
>
50
>
50
Current consumption (15 V SWD supply) See Page V7-T9-61 See Page V7-T9-61 See Page V7-T9-61 See Page V7-T9-61 See Page V7-T9-61
Function Element
Contacts 1 changeover contact 1 changeover contact 1 changeover contact
Lifespan mechanical/electrical (operations) 1 x 10
6
1 x 10
6
——1 x 10
6
LED display No No Yes Yes Yes
Diagnostics Yes Yes No No Yes
Mounting Front mount Base mount Front mount Base mount Front mount