Pushbuttons and Indicating Lights
30.5 mm Corrosion Resistant Watertight/Oiltight—E34
Contact Blocks
Notes
1
All 10250T contact blocks shown are suitable for use on standard 10250T and E34 operators. These contact blocks are not suitable for Class I Division 2
type 10250T or E34 devices.
2
Contact blocks with spade terminals are limited to a maximum of one contact block per operator and minimum spacing between devices is 2.5 in (63.5 mm).
Not suitable for use in 10250T or E34 enclosures. Also available in amber housing. Not available with fingerproof shrouds.
3
Special function contact blocks are not suitable for use with roto-push operators, three-position push-pull operators, or four-position selector switches.
4
ECNO contact blocks are not suitable for use with two-position joysticks or when operators are used with padlock attachments.
5
Special purpose 10250T44 contact blocks are not suitable on selector switches or roto-push operators. Okay to use with three-position push-pull operators only
on low voltage (30V or less) circuits.
Symbol Circuit Description
1
Standard Logic Level
Pressure Terminal
Catalog Number
Spade Terminal
2
Catalog Number
Pressure Terminal
Catalog Number
Spade Terminal
2
Catalog Number
1NC Stack up to six blocks (six circuits)
unless otherwise noted.
10250T51 10250T59 10250T51E 10250T59E
1NO Stack up to six blocks six circuits)
unless otherwise noted.
10250T53 10250T60 10250T53E 10250T60E
NO-NC Stack up to six blocks (12 circuits)
unless otherwise noted.
10250T1 10250T40 10250T1E 10250T40E
2NC Stack up to six blocks (12 circuits)
unless otherwise noted.
10250T3 10250T42 10250T3E 10250T42E
2NO Stack up to six blocks (12 circuits)
unless otherwise noted.
10250T2 10250T41 10250T2E 10250T41E
Special Function Blocks
3
LONC Late opening NC. Stack up to six
blocks (six circuits) unless
otherwise noted.
10250T71
3
10250T71E
3
ECNO-
NC
Early closing NO and standard NC.
Stack up to six blocks unless
otherwise noted.
10250T47
34
10250T47E
3
ECNO-
NO
Early closing NO and standard NO.
Stack up to four blocks unless
otherwise noted.
10250T57
34
10250T57E
3
2LONC Two late opening NC contacts.
Stack up to six blocks unless
otherwise noted.
10250T45
3
10250T45E
3
LONC-
ECNO
Overlapping contacts. Stack up to
four blocks unless otherwise noted.
10250T55
34
10250T55E
3
Special Purpose Blocks
5
2NO-
2NC
Four circuits in single block depth.
Rated 300V max. Stack up to four
blocks unless otherwise noted.
10250T44
5
10250T1
Blank
No
Plunger
Blank
No
Plunger
Blank
No
Plunger