Cut Sheet

V7-T3-28 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—July 2015 www.eaton.com
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V7-T3-28 Volume 7—Logic Control, Operator Interface and Connectivity Solutions CA08100008E—July 2015 www.eaton.com
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3.3
Control Relays and Timers
Programmable Relays
Technical Data and Specifications
easy802/806 Programmable Relays with SmartWire-DT
Note
1
Use power-feed modules if the cable length of the SWD line causes excessive voltage drop.
Description Unit Specification
Ambient Climatic Conditions
Cold to IEC 60068-2-1, heat to IEC 60068-2-2, damp heat, constant, to IEC 60068-2-78;
cyclical to IEC 60068-2-30; temperature change to IEC 68000-2-14
Operating ambient temperature °C (°F) –25 ° to +55 ° (–13 ° to +131 °)
Condensation Prevent condensation by means of suitable measures
LCD display (reliable legible) °C (°F) 0 ° to +55 ° (32 ° to +131 °)
Storage °C (°F) –40 ° to +70 ° (–40 ° to +158 °)
Relative humidity, noncondensing (IEC EN 60068-2-30) % 5 to 95
Air pressure (in operation) hPa 795 up to 1080
Ambient Mechanical Conditions
Protection type EN 50178, IEC 60529, VBG4 IP20
Vibrations (IEC EN 60068-2-6)
Constant amplitude: easy800-SWD; 3.5 mm Hz 5–8.4
Constant acceleration: easy800-SWD: 1g Hz 8.4–150
Mechanical shock resistance (IEC EN 60068-2-27)
semi-sinusoidal 15g / 11 ms
Shocks 18
Drop (IEC EN 60068-2-31) Drop height mm 50
Free fall, packaged (IEC EN 60068-2-32) m 0.3
Electromagnetic Compatibility (EMC)
Electrostatic discharge (ESD), to IEC EN 61000-4-2
Air discharge kV 8
Contact discharge kV 6
Electromagnetic fields (RFI), to IEC EN 61000-4-3
0.8–1.0 GHz V/m 10
1.4–2.0 GHz V/m 3
2.0–2.7 GHz V/m 1
Radio interference suppression EN 55011 Class B
Burst, to IEC EN 61000-4-4
Supply cables kV 2
Signal cables kV 2
easyNet kV 2
SWD-line kV 2
Power pulses (surge), to IEC EN 61000-4-5 (supply cables, symmetrical) kV 1
Radiated RFI, to IEC EN 61000-4-6 V 10
Insulation Resistance
Overvoltage category III
Pollution degree 2
Clearance in air and creepage distances EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance EN 50178
Terminal Capacity
Solid, minimum to maximum mm
2
0.2 to 1.5 (AWG 24–16)
Flexible with ferrule, minimum to maximum mm
2
0.2 to 1.5 (AWG 24–16)
DC POW Rated Operational Voltage
Rated value U
e
Vdc, (%) 24 DC (–15/+20)
Permissible range
1
Vdc 20.4–28.8
Residual ripple %
<
5
Protection against polarity reversal Yes
Input current
At rated operating voltage mA easy802: 500 / easy806: 900
Inrush current and duty factor 12.5 A for 6 ms
Voltage dips (IEC EN 61131-2) ms 10