3.3
Control Relays and Timers
Programmable Relays
Technical Data and Specifications
MFD-80, MFD-CP4, MFD-CP8
MFD-Titan I/O Modules
MFD-CP4 and CP8 Communication Modules
Note
1
Relay = 8 A with resistive load, 3 A with inductive load.
Transistor outputs = 0.5 A/24 Vdc, maximum four outputs switchable in parallel.
Type MFD-80… MFD-CP4/CP8
Connection cables
Solid 0.2–4.0 mm
2
(AWG 22–12)
Flexible 0.2–2.5 mm
2
(AWG 22–12)
Degree of protection IP65 IP20
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4 EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
Ambient operating temperature Clearly legible at –5 °C to +50 °C –25 °C to +55 °C
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C
Hazardous location CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C CSA Class I, Div. 2, Groups A, B, C, D; Temp. Code T3C
Type MFD-AC-R16 MFD-R16 MFD-RA17 MFD-T16 MFD-TA17
Supply voltage Supply via
MFD-CP8 module
Supply via
MFD-CP8 module
Supply via
MFD-CP8 module
Supply via
MFD-CP8 module
Supply via
MFD-CP8 module
Heat dissipation 0.5 W 0.5 W 0.5 W 0.5 W 0.5 W
Continuous current outputs
1
8 A8 A8 A0.5 A0.5 A
Short-circuit proof with
power factor 1
Line protection
B16, 600 A
Line protection
B16, 600 A
Line protection
B16, 600 A
——
Short-circuit proof with
power factor 0.7…0.7
Line protection
B16, 600 A
Line protection
B16, 600 A
Line protection
B16, 600 A
——
Connection cables
Solid 0.2–4.0 mm
2
(AWG 22–12) 0.2–4.0 mm
2
(AWG 22–12) 0.2–4.0 mm
2
(AWG 22–12) 0.2–4.0 mm
2
(AWG 22–12) 0.2–4.0 mm
2
(AWG 22–12)
Flexible 0.2–2.5 mm
2
(AWG 22–12) 0.2–2.5 mm
2
(AWG 22–12) 0.2–2.5 mm
2
(AWG 22–12) 0.2–2.5 mm
2
(AWG 22–12) 0.2–2.5 mm
2
(AWG 22–12)
Degree of protection IP20 IP20 IP20 IP20 IP20
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1,2,3,4
Ambient operating temperature –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C –25 °C to +55 °C
Transport and storage temperature –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C –40 °C to +70 °C
Mounting Snap fitted to
MFD-CP8 module
Snap fitted to
MFD-CP8 module
Snap fitted to
MFD-CP8 module
Snap fitted to
MFD-CP8 module
Snap fitted to
MFD-CP8 module
Type MFD-80… MFD-CP4-… MFD-CP8… MFD-AC-CP8…
Supply voltage Supply from -CP 24 Vdc 24 Vdc 100–240 Vac
Heat dissipation 3 W 1.5 W 3 W 8 VA
Mounting Front mounting in 2 x 22.5 mm
Standard drill holes
Snap fitted to MFD-80 Snap fitted to MFD-80 or on 35 mm DIN rail or screw mounting with
ZB4-101-GF1 mounting feet