Control Relays and Timers
Machine Tool Relays
Accessories
Pneumatic Timer Attachment
Maximum Ampere Ratings
Attachment mounts on top of
any Freedom Series relay
(top-mounted auxiliary
contacts can not be installed
on device when timer is
used). Timer unit has DPST
timed contacts—circuits in
each pole must be the same
polarity. Units are convertible
from OFF to ON delay or
vice-versa.
Finger Protection Shields
Snap-on shields for both
contactors and starters
provide IEC Type IP20
Finger Protection. Prevents
accidental contact with line/
load terminals.
Adhesive Dust Cover
These adhesive stickers
come 25 to a package and
provide extra protection from
contaminants when applied
to the sides of Freedom D15.
Adhesive covers are easily
applied to side opening
where auxiliaries are not
installed and provide extra
protection from metal filings
and other debris.
Solid-State ON DELAY Timer
1
This timer is designed to be
wired in series with the
load (typically a coil). When
the START button is pushed
(power applied to timer), the
ON delay timing function
starts. At the completion of
the set timing period, timer
and series wired load will
both be energized.
Timing Range
Catalog
Number
0.1 to 30 seconds C320TP1
10 to 180 seconds C320TP2
Volts AC
Description 120 240 480 600
Make 30 15 7.5 6
Break 3 1.5 0.75 0.6
C320 Pneumatic
Timer Attachment
Application
Catalog
Number
D15 C320LS1
Description
Catalog
Number
25 to a package C320DSTCVR
Timing Range
Catalog
Number
234
0.1 to 1.0 seconds C320TDN1_
1 to 30 seconds C320TDN30_
30 to 300 seconds C320TDN300_
5 to 30 minutes C320TDN3000_
Solid-State Timer
Metal Mounting Plate
Fits all D15 multipole relays.
Mounting Channel (DIN Rail)
Designed for DIN rail
mounting of Freedom
Series relays.
Transient Suppressor Kits
These kits limit high voltage
transients produced in the
control circuit when power is
removed from the contactor
or starter coil. There are three
separate suppressors for use
on 24–120 V, 208–240 V or
27–480 V coils respectively.
These devices mount directly
to the coil terminals.
Notes
1
Side mounted on Freedom Series NEMA 00–2, D15, IECA-K and C25D, C25E and C25F frame.
2
Add operating voltage suffix to catalog number; A = 120 V, B = 240 V, E = 208 V.
3
Rated 0.5 ampere pilot duty—not to be used on larger contactors.
4
Terminal connections are quick connects only. Two per side.
5
Suppressor is compatible with coil voltages/ranges as shown, both 50 and 60 Hz.
Description
Catalog
Number
Metal mounting plate C321MP1
C32MP1
Description
Catalog
Number
1 meter length XBANS3575P
DIN Rail
Description
Coil Voltage
50/60 Hz
5
Catalog
Number
Transient 24/120 V C320TS1
Suppressor 208/240 V C320TS2
277/480 V C320TS3
C320TS2