3.8
Control Relays and Timers
Ti m i n g Rel ay s
Contents
Description Page
Universal TR Series . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-172
TR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-176
TMR5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-179
TMR6 Series
Catalog Number Selection . . . . . . . . . . . . . . . . V7-T3-184
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V7-T3-184
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-184
Technical Data and Specifications . . . . . . . . . . V7-T3-184
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-184
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-184
TMRP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V7-T3-185
TMR6 Series
Product Description
Most electronic time delay
relays with an OFF delay
function require input voltage
to be applied continuously
in order to operate correctly.
However, there are many
applications where this is
not possible—-keeping a
relay energized for some
amount of time after input
voltage has been removed.
Eaton’s TMR6 true OFF
delay product provides
this function even when
input voltage is removed.
It duplicates the operation
of the older OFF delay
pneumatic time delay relays.
Features
Provides OFF delay
function without requiring
input voltage during OFF
time delay
Duplicates operation of
pneumatic OFF delay
timers
Each unit has eight timing
ranges built in, covering
0.05 seconds to
30 minutes
Selecting a range is easy
using a rotary switch
(no math is required or
DIP switches to set)
Uses industry-standard
8-pin octal socket
10 A DPDT output contacts
Timing Ranges
Select one of the eight timing
ranges using the selector
knob, and then adjust the
time within that range for an
accurate delay setting.
Timing Ranges
Dial Setting Timing Range
A 0.05–5 sec.
B 0.1–10 sec.
C 0.3–30 sec.
D 0.6–60 sec.
E 1.8–180 sec.
F 3–300 sec.
G 0.1–10 min.
H 0.3–30 min
Operation
True OFF Delay
Upon application of input
voltage, the relay is
energized. When the input
voltage is removed, the
preset time begins. At the
end of the preset time, the
relay is de-energized.
Voltage must be applied for
a minimum of 0.1 second to
assure proper operation.
Any application of the input
voltage during the preset
time will keep the relay
energized and reset the time
delay. No external trigger
switch is required.
True OFF Delay
Standards and Certifications
cRUus
UL listed (with Eaton socket)
RoHS compliant
CE marked
Delay
Input
Power
(Voltage)
Output
(Load)
ON
OFF
ON
OFF
with
Eaton
socket