PLC, I/O and Communications Products
XI/ON Series Remote I/O
Digital Output Modules, continued
Notes
1
The supply terminal (U
L
) provides power for the module electronics and for the consumers at the outputs. The total current required for each module consists of the sum of all partial currents.
2
Part of the XI/ON module’s electronics is supplied with module bus voltage (5 Vdc), the other part through the supply terminal (U
L
).
3
To increase the maximum output current to up to 1A, two outputs can be connected in parallel.
Description Unit XN-16DO-24VDC-0.5A-P XN-32DO-24VDC-0.5A-P XNE-8DO-24VDC-0.5A-P XNE-16DO-24VDC-0.5A-P
Channels Number 16 32 8 16
Rated voltage at supply terminal (U
L
) Vdc 24 24 24 24
Rated current drawn from supply terminal (for
0 mA load current) (I
L
)
1
mA
<
30
<
50
<
3 (all outputs OFF)
<
3 (all outputs OFF)
Rated current drawn from module bus (I
MB
)
2
mA
<
120
<
30
<
15
<
25
Insulation test (U
i
) Vac 500 500 500 500
Heat dissipation W Normally 4 Normally 5 Normally 1.5 Normally 2.5
Output voltage
High level Vdc >U
L
–1 >U
L
–1 >U
L
–1 >U
L
–1
Output current
High level (rated) A 0.5 0.5 0.5
3
0.5
3
High level (permissible range) A <0.6 <1.0 <1.0 <1.0
Low level mA————
Back-up fuse ————
Surge current (I
S
)A————
Number of parallel-switchable outputs
(maximum)
—2 ——
Total module current A 8 10 4 4
Delay for signal changeover, resistive load
From Low to High level µs <100 <300 <300 <300
From High to Low level µs <100 <300 <300 <300
Load resistance range >48 ohm >48 ohm >48 ohm >48 ohm
Utilization factor (%) g 100 See total module current 100 50%, max. 4A
The following can be connected: Resistive loads/Inductive loads/Lamp loads
Resistive load ohm >48 >48 >48 >48
Inductive load H <1.2 <1.2 As for DC13 to IEC 60947-5-1 As for DC13 to IEC 60947-5-1
Lamp load (R
LL
) W <3 <6 <6 <6
Switching frequency
For resistive load (f) Hz <100 (R
LO
<1 kohm) <100 (R
LO
<1 kohm) <100 <100
For inductive load Hz As for DC13 to IEC 60947-5-1 As for DC13 to IEC 60947-5-1
For lamps Hz——<10<10
Number of diagnostic bits 4 8
Diagnostics Yes Yes
Outputs to EN 61131-1 Short-circuit proof Short-circuit proof Short-circuit proof Short-circuit proof
Retriggering after elimination of
short circuit (I
i
)
Self-acting Self-acting Self-acting Self-acting
Basic modules
With C connection XN-B3…-SBC XN-B6…-SBCSBC Already built in Already built in